SYMPTOM

CAUSE

SOLUTION

Dosing

Water flowing back 

into the product tank.

Suction valve or valve 

seal dirty, worn, absent or 

wrongly fitted.

To be cleaned or replaced.

No suction of product.

The motor piston has 

stopped working.

See 

Troubleshooting Motor 

piston.

Air tightness problem in 

the suction hose.

Check the suction hose and 

the tightening of its nuts. 

Change the suction hose 

when it becomes too 

supple or rigid depending 

on the additives dosed. 

This can interfere with 

the watertightness of the 

connector on the Dosatron.

Suction hose obstructed or 

strainer blocked.

Clean it or replace it.

Suction valve seal worn, 

wrongly fitted or clogged.

Clean it or replace it.

Dosing piston seal wrongly 

fitted, clogged or swollen. Clean it or replace it.
Dosing pump body 

scratched. 

Replace it.

Leaks

Leaks close to the quick 

coupling ring under the 

pump body.

Dosing body seal 

damaged, wrongly 

positioned or absent.

Position it correctly or 

replace it.

Leaks between the 

dosing adjustment 

sleeve and the dosing 

locker.

Dosing pump body 

seal damaged, wrongly 

positioned, absent or 

dosing pump body grooves 

scratched.

Position it correctly or 

replace it.

Leaks between the 

body housing and the 

top cap.

Top cap seal damaged, 

wrongly assembled or 

absent.

Position it correctly, clean 

seal groove or replace it.

DOSATRON INTERNATIONAL DECLINES ALL 

RESPONSIBILITY IN THE EVENT OF USE THAT IS NOT 

COMPLIANT WITH THE INSTRUCTIONS FOR USE.

Limited Warranty

DOSATRON INTERNATIONAL 

S.A.S. agrees to replace any part 

recognised to be defective originally  

for a period of twelve months from 

the date of purchase by the initial 

purchaser.

To obtain the replacement under the 

warranty, the appliance or spare part 

must be returned with proof of initial 

purchase  to the manufacturer or 

authorized distributor.

It may  be recognised as defective 

after examination by the technical 

services of the manufacturer or 

distributor.

The appliance must be rinsed to 

remove any chemicals and sent to 

the manufacturer or to the distributor 

with postage paid, then it will be 

returned free of charge after repair if 

it is covered by the warranty.

The purpose of operations carried 

out under the warranty may not be to 

extend the lifetime. 

This warranty applies only to 

manufacturing defects.

This warranty does not cover 

defects found to be due to abnormal 

installation of the appliance, 

inappropriate use of tools, lack of 

maintenance or defective installation 

or environmental accidents or 

corrosion by foreign bodies and 

liquids found within or in proximity to 

the appliance.

For the dosing of aggressive 

products, please consult your 

vendor before any use to confirm 

compatibility with the dosing pump.

The seals (wearing parts) are not 

covered under warranty, nor is 

damage caused by water impurities 

such as sand, minerals and any other 

abrasive particles.

A filter (e.g. 300 mesh - 60 microns 

depending on your water quality) 

must be installed before the 

appliance.

DOSATRON INTERNATIONAL 

S.A.S. declines any responsibility if the 

appliance is not used in compliance 

with the recommendations and 

tolerances in the owner’s manual.

There is no explicit or implicit 

guarantee relating to other products 

or accessories used with DOSATRON 

INTERNATIONAL S.A.S appliances. 

Summary of Contents for D25+ Series

Page 1: ...utiliza o DOSATRON INTERNATIONAL S A S Rue Pascal B P 6 33370 TRESSES BORDEAUX FRANCE Tel 33 0 5 57 97 11 11 Fax 33 0 5 57 97 11 29 33 0 5 57 97 10 85 info dosatron com www dosatron com DOSATRON INTER...

Page 2: ...ge 37 Deutsch Seite 69 Italiano Pagina 101 Espa ol P gina 133 Nederlands Pagina 165 197 Polski Strona 229 Portugu s P gina 261 Annexes Enclosure Anhang Anejos Allegati Bijvoegsel Za czniki Anexos 293...

Page 3: ...ing pumpvia your Dosatron dosing pump This dosing pump product just like all Dosatron dosing pumps has undergone post manufacturing testing Please read this user s manual carefully to ensure correct o...

Page 4: ...llation tips 22 PUTTING INTO SERVICE Using for the first time 23 Use 23 Adjusting the dosing rate 24 Dosing principle 24 MAINTENANCE Recommendations 25 Removing the suction hose 26 Removing Refitting...

Page 5: ...the technical performances of the appliance The Animal Health Line dosing pumps with a reference containing the index N after the dosing indication are compliant with the regulation EC No 1935 2004 c...

Page 6: ...COMPOSITION 1 DOSATRON 1 mounting bracket for DOSATRON 1 suction hose for concentrate 1 strainer 1 quick start guide D25 PACKAGING 520 mm x 170 mm x 180 mm 20 5 x 6 7 x 7 1 WEIGHT approx 2 kg for the...

Page 7: ...ype of installation It is the responsibility of the user to replace the dosing part seals annually to ensure accurate dosing The adjustment of the Dosatron s dosing is the sole responsibility of the u...

Page 8: ...out tools 2 WATER WITH HIGH PARTICLE CONTENT A filter sieve must be installed upstream of the DOSATRON when water has a high particle content e g 300 mesh 60 microns depending on your water quality If...

Page 9: ...body Fig 1 A into the corresponding holes in the bracket Fig 1 B Remove the plastic caps Fig 1 C which block the openings in your DOSATRON before connecting to the water supply line INSTALLATION OF T...

Page 10: ...osing body into the pump body taking care to align the aligning pins If needed to see the pins better unscrew the dosing adjustment sleeve so as to reach the value of 3 or 1 33 Fig 3 Push the quick co...

Page 11: ...he lowest water level height in relation to the drinking troughs If your flow is above DOSATRON limits see the OVERFLOW To prolong the working life of the DOSATRON it is advisable to install a filter...

Page 12: ...tted Partially open the water inlet Press the bleed button on the top cap Fig 10 When a constant flow of water is seen coming from around the bleed button no more spitting of air release the button Sl...

Page 13: ...Before putting the DOSATRON into operation after a long non use period remove the motor piston and soak it in lukewarm water at 40 C 104 F for a few hours This helps to remove any deposits which may h...

Page 14: ...o by opening the fast priming valve situated downstream of the Dosatron Remove the dosing part DISMANTLING REFITTING THE DOSING PART Remove the top cap and the motor Disconnect the connectors at the D...

Page 15: ...operly in its groove Fig 24 Finish by refitting the suction valve and its nut Fig 25 DISMANTLING REFITTING THE DOSING PISTON Before performing any maintenance on the DOSATRON it is essential to refer...

Page 16: ...ack of the motor Motor piston blocked Bleed the dosing pump by opening the clear water and fast priming valves situated downstream and upstream of the Dosatron and then dismantle the top cap in order...

Page 17: ...lace any part recognised to be defective originally for a period of twelve months from the date of purchase by the initial purchaser To obtain the replacement under the warranty the appliance or spare...

Page 18: ...ximate guide n Calculation of water flow in GPM Number of clacks 15 seconds x 4 x 0 45 x 3 8 2 Motor capacity in litres Calculation for 1 minute 2 clacks 1 cycle Conversion litres to gallons A SIMPLE...

Page 19: ...DOSATRON INTERNATIONAL S A S 37 DOSATRON INTERNATIONAL S A S 38 Courbes Curves Diagramm Curva Curvas Grafiek Krzywe Gr ficos 295 Annexes Enclosure Anhang Anejos Allegati Bijvoegsel Za czniki Anexos...

Page 20: ...2250 2500 2750 Flow Rate US GPM D25AL5N Courbes de Pertes de charges 5 Pressure drop curves at 1 20 D bit Water ow rate Durchsatz Portata Caudal Doorstroming in GPM o Strata ci nienia Perdas de press...

Page 21: ...Water ow Betriebswasserdurchsatz Portata d acqua di funzionamento Caudal de agua de funcionamiento Waterdoorstroming Maks przep yw Caudal m x l h l Std l uur Viscosit Viscosity Viskosit t Viscosit Vi...

Page 22: ...nto no constituye un compromiso contractual y se suministra solamente a t tulo orientativo La sociedad DOSATRON INTERNATIONAL se reserva el derecho de modificar sus aparatos en cualquier momento Dit d...

Reviews: