Troubleshooting
SYMPTOM CAUSE
SOLUTION
Motor piston
The Dosatron is not on “ON” Put the button on “ON”
Air has not been
Bleed air from unit,
bled from unit
by bleed button
Maximum flow
1. Reduce flow, restart unit
exceeded.
2. Return the Dosatron
to your distributor
Motor piston stalled
Return unit to your
or damaged
service center for repair
Leak at the security
1. Check or clean
valve
the valve seal
2. Return the Dosatron
to your distributor
No water at
Network pressure is
Increase the pression
the outlet
not sufficient
to more than 0.3 bar
Injection
Water flowing back Contaminated, worn,
Clean or replace them
into concentrate or missing check
container valve
parts
No suction of
The motor piston
See
motor piston
section
concentrate has
stopped
Air leak (inlet) in the
Check the tightness be-
suction
tube
tween nut and suction hose
Blocked suction tube or
Clean or replace it
clogged strainer
Missing or worn
Clean or replace it
suction check valve seal
Note:
the Dosatron Compact is equipped with a security valve integrated in
the Dosatron inlet, which will open and let the water flow through in case of
inopportune stopping of the motor. This security-“bypass” needs a differential
pressure of 1.5 bar below which the valve will not operate.
DOSATRON does
not start or stops
Summary of Contents for D 07 RE 125
Page 1: ...NT Compact FR 0310 D 07 RE 125 D 07 RE 5 manuel d utilisation FR 0 7 m3 h 3 GPM...
Page 10: ...DOSATRON INTERNATIONAL 10 CLAT S D 07 RE 125...
Page 17: ...NT Compact GB 0310 D 07 RE 125 D 07 RE 5 owner s manual GB 0 7 m3 h 3 GPM...
Page 26: ...DOSATRON INTERNATIONAL 10 PARTS DIAGRAM D 07 RE 125...
Page 33: ...NT Compact AL 0310 D 07 RE 125 D 07 RE 5 gebrauchsanweisung AL 0 7 m3 h 3 GPM...
Page 42: ...DOSATRON INTERNATIONAL 10 SCHEMATA D 07 RE 125...