![dosatron D 07 RE 125 Owner'S Manual Download Page 25](http://html1.mh-extra.com/html/dosatron/d-07-re-125/d-07-re-125_owners-manual_2523994025.webp)
IMPORTANT !
Use no tools
Adjustment must be made when there is no pressure in the Dosatron.
- Turn off the water supply and allow the pressure to drop to zero.
- Unscrew the
blocking ring.
- Screw or unscrew
the adjusting nut
so as to bring the
top of the nut into
line with the desi-
red injection rate.
- Tighten the bloc-
king ring.
ADJUSTING THE INJECTION RATE
©
DOSATRON INTERNATIONAL /
9
PREMIÈRE MISE EN SERVICE
ATTENTION: Check that the bypass
is in “ON”-position.
- Partially open the water inlet
valve.
- Press the bleed button on the top
of the DOSATRON.
- When a constant flow of water is
seen coming from around the bleed button (no more
«spitting» of air), release the button.
- Open the water inlet valve slowly, the DOSATRON
is self-priming.
- Operate the DOSATRON until the product to be injected is drawn up into
the injection part (the product is visible through the plastic tube).
- The DOSATRON makes a characteristic “click-clack” noise when working.
NOTE:
The time required to prime the suction tube depends on the water
flow-rate, the ratio setting and the length of the suction tube. To bleed the
air from the suction tube and accelerate the priming, set the injection rate
at maximum. Once the DOSATRON is primed, adjust to the required injec-
tion rate (see § ADJUSTING THE INJECTION RATE).
ON
OFF
Summary of Contents for D 07 RE 125
Page 1: ...NT Compact FR 0310 D 07 RE 125 D 07 RE 5 manuel d utilisation FR 0 7 m3 h 3 GPM...
Page 10: ...DOSATRON INTERNATIONAL 10 CLAT S D 07 RE 125...
Page 17: ...NT Compact GB 0310 D 07 RE 125 D 07 RE 5 owner s manual GB 0 7 m3 h 3 GPM...
Page 26: ...DOSATRON INTERNATIONAL 10 PARTS DIAGRAM D 07 RE 125...
Page 33: ...NT Compact AL 0310 D 07 RE 125 D 07 RE 5 gebrauchsanweisung AL 0 7 m3 h 3 GPM...
Page 42: ...DOSATRON INTERNATIONAL 10 SCHEMATA D 07 RE 125...