Fault description
Cause
Remedy
Air escapes on the material
flow control (6) or the valve
(7).
O-ring (33, 34) is defec-
tive.
Replace O-ring.
Sparking on the electrode
Cascade (10) is defective.
Replace cascade.
Electrode (21) is defective.
Replace electrode.
“H.V.” LED lights up, even
though the gun trigger is
released.
Air leakage on gun or air
hose
Rectify air leakage.
Flow switch in the con-
troller is defective.
Replace flow switch.
“Applicable documents”, oper-
ating instructions of the controller
Flow switch is contami-
nated with oil, water or dirt.
Replace flow switch.
“Applicable documents”, oper-
ating instructions of the controller
Warning tone or alarm on
the controller
Basic housing (24) conta-
minated with paint
Clean basic housing.
Paint hose contaminated
with paint
Clean paint hose.
Spray distance is too close
Increase spray distance or
decrease voltage value.
Water build-up in the air
ducts of the basic housing
Drain water on the maintenance
unit. Blow out the air ducts.
Electrode (21) contami-
nated with paint
Clean or replace electrode (21).
Worn out seal kit (25).
Replace seal kit.
9.3
Troubleshooting
9.3.1 Replace needle, nozzle and seal kit
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Faults
11/2019
EcoGun AS MAN EC - MSG00022EN