Fault description
Cause
Remedy
Worn out seal kit (24).
Replace seal kit.
Warning tone or alarm on the
electrostatic controller (if paint
supply for non-flammable paints
is isolated)
Basic housing (23) con-
taminated with paint
Clean basic housing.
Paint hose contaminated
with paint
Clean paint hose.
Spray distance is too
close
Increase spray distance or
decrease voltage value.
Water build-up in the air
ducts of the basic
housing
Drain water on the mainte-
nance unit. Blow out the air
ducts.
Grounded object near
the paint supply
Ensure minimum distance of
300mm between isolated paint
supply and grounded objects.
Worn out seal kit (24).
Replace seal kit.
9.3
Troubleshooting
9.3.1 Replace needle, nozzle and seal kit
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Eye protection
Anti-Static Safety Boots
Requirements:
Disassembly
Fig. 25: Ground electrode
Faults
11/2019
EcoGun AS MAN DC - MSG00023EN
26/56