10.2 Disassembly
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Use ear protection
Eye protection
Respiratory protection device
Protective workwear
Anti-Static Safety Boots
1. Purge spray gun
2. Switch off electrostatic controller.
3. Disconnect the compressed air supply
and material feed. Secure against recon-
nection.
4. Disconnect all lines.
10.3 Disposal
ENVIRONMENT!
Incorrect disposal
Improper waste disposal threatens the
environment and prevents re-use and
recycling.
– Always dispose of components in
accordance with their characteristic.
– Collect leaked out operating and auxil-
iary materials completely.
– Dispose of operating and auxiliary
materials according to the disposal
provisions in force.
– In case of doubt, refer to the local dis-
posal authorities.
11
Technical data
11.1 Dimensions and weight
Fig. 51: Dimensions
Detail
Value
Weight
540g
Height
231mm
Length
212mm
Width
62mm
11.2 Connections
Connection
Nominal
width
Material
G3/8"
Air
G1/4''
11.3 Operating conditions
Detail
Value
Maximum allowable mate-
rial temperature
40°C
Operating temperature
0 - 40°C
Relative humidity
40 - 80%
Technical data
11/2019
EcoGun AS MAN DC - MSG00023EN