GUANGDONG DOROSIN ELECTRICAL
APPLIANCE CO., LTD.
20
Fault
Code
The failure
How to do with it?
E1
Temperature sensor breakdown
To replace with new temperature sensor.
E2
Humidity sensor breakdown
To replace with new humidity sensor.
E3
Phase sequence or phase loss
protection (Excluded 220V)
Swap phase sequence
E4
Full water tank
Pour out the water
E5
High voltage protection
Check refrigerant pressure
E6
Low voltage protection
Check refrigerant pressure
11 TROUBLESHOOTING
Please do not worry if you meet following problems in the use of dehumidifier. When
confirmed as failure, timely contact for repairing.
Problems
Phenomenon/Reason
Solutions