4.2 FEATURES:
1. If the set humidity is higher than the current ambient humidity, the dehumidifier will enter the
"wet control state" and will not run.
2. When entering the dehumidification mode, the fan is turned on for 5 seconds to start the
compressor; when the dehumidifier stops working, the dehumidifier will first turn off the
compressor, and then turn off the fan after 30 seconds;
3. After the compressor is turned off, it takes 3 minutes to restart. When the compressor is
running for 72 hours, the system will automatically resume after 30 minutes of forced stop.
4. When running at a lower temperature, the machine will automatically detect the temperature
of the system. When the defrosting temperature is reached, the dehumidifier will automatically
stop and defrosting. At this time, the “snow pattern” will light up and the “defrosting pattern”
will shine. After the defrosting, the dehumidifier starts automatically.
5. The system has a memory function, which can restore the previous running state after power