background image

T2 ES/ T4 ES 

TURBINES

USER MANUAL

Summary of Contents for T2 ES

Page 1: ...T2 ES T4 ES TURBINES USER MANUAL ...

Page 2: ......

Page 3: ...r type 5 Delivery inspection 6 Product Overview 6 Drying methods 7 Suction drying 7 Pressure drying 7 Installation 8 Accessories and consumables 9 To Use CTR T ES menus and operation 9 Network functions 15 How to network machines 16 Alarms 17 Service Reminder 17 Maintenance and service 18 Fault finding 19 Technical data 20 Interface Map for CTR A2ES CTR A4 ES and CTR A ES 21 ...

Page 4: ...tworked operation and it is prepared for remote monitoring and control The unit has cable parking integrated with its foldable carrying handle and its low weight makes it easy to carry and install Durable yet flexible feet protect floor surfaces while also allowing stacking of machines The turbine is naturally as robust in its design as its predecessors a prerequisite for a long service life Thank...

Page 5: ...oduct at time of delivery and before use to ensure its good function The product warranty does not cover damage resulting from use of faulty products Changes or modifications to the equipment must not be made without written consent by Corroventa Avfuktning AB The product technical data and or installation and operation instructions can be changed without prior notice This manual contains informat...

Page 6: ... and leveled so that it cannot fall over 11 Keep children animals and spectators away from the work place while installation is undertaken 12 If the turbine is broken if the power connector or the cable is damaged contact the retailer Do not repair the equipment if you have not received specific training by the manufacturer 13 Be careful not to damage the power cable The cable must not go through ...

Page 7: ...ns even well below the freezing point while the capacity of a condensation dryer inevitably decreases rapidly with falling temperature something that is depicted in the diagram below to the left As a rule of thumb a general aid in the selection of type it can be said that adsorption is the primary choice for drying of unheated spaces or when material is to be dried The latter is motivated by the f...

Page 8: ... pc Product Overview Below pictures present CTR T ES with all its external features and controls The CTR T2 ES is shorter than the CTR T4 ES but all the external features are the same Cooling air filter hatch Durable poly urethane feet Inlet Control Panel Outlet Foldable carrying handle with integrated cable parking Locks Process air filter hatch Power switch on off ...

Page 9: ...tor is critical to prevent water from being sucked into the turbine and damage its motor The dryer is installed for normal drying of room Pressure drying For pressure drying the turbine is installed so that it is fed with dry air from the dryer and then presses this down into the construction This makes the construction temperature rise and the drying goes faster Wet and cooled air leaks into the ...

Page 10: ...before the work is commenced Contrary to its predecessors the CTR T ES is not equipped with a manually resettable overheating protection as this no longer is necessary The turbine provides itself with cooling air and prevents overheating by automatically adjusting its speed if the temperature should still rise too high For best drying performance the user should however still verify that the airfl...

Page 11: ...ll immediately lead back to the default view something that can be good to remember if unfamiliar with the menu system In many of the views there is an Info button which presents information that may be of use to the inexperienced user If the backlight of the display has timed out the first button push serves only to light up the display After 10 minutes if no button is pushed a key pad lock is ac...

Page 12: ...t to operate on Timer Alarm Machine has detected an error Speed indicator Indicates what speed the turbine is operating at Water separator Visible when the machine is connected to WS 4 ES water separator through system cable allowing the turbine to count the number of times the water separator has pumped and also to present when it last pumped which is useful for evaluation of drying progress time...

Page 13: ... and increase the speed level The current speed level is depicted on the vertical bar to the left The horizontal indicator presents the current pressure level compared to the maximum pressure achievable for the given turbine speed When set to flow mode the left and right buttons below the display changes the setpoint flow highlighted with black background The same principal applies to Relation mod...

Page 14: ...ate how much water has been removed In addition the turbine can also present at what date and time the water separator was last emptied in order for the user to assess whether or not there is any more water to be removed If this functionality is activated there when there is no WS 4ES connected the turbine will remain in standby Timer on off and quiet mode If for some reason the machine must not o...

Page 15: ...eate The creation can take up to one minute When the creation process is through a slave selection menu is presented If there is no need to change the settings on any of the slaves push Escape If changes are required push Select and use the left and right arrow buttons to choose the machine to edit When selecting a slave its display backlight will start blinking as an acknowledgement to the user S...

Page 16: ...te at which the counters were reset After the date the number of hours elapsed since this reset is presented so as to allow for a quick comparison To reset the work counters push Reset Acknowledge the intent to reset the counters by push of OK in the following confirmation screen At the bottom the machine life time counters for energy and hours are presented These counters are not resettable Stati...

Page 17: ...s requires no pre configuration or other preparations When installed the machines are simply connected with system cables and then a simple push of the Create button in the Network menu of the intended Master machine is all that is required The Master is the machine selected to control the others and all machines can be used to this purpose For use of Relation and Pressure drying modes the Master ...

Page 18: ...etwork menu depicted below If this menu is not found the machine is set to Basic menu setting To change this select Setup and Maintenance menu and change the menu system setting to Advanced 5 In the Network menu push Create and then wait while the machine sets up the network 6 When the network is created at the top of the screen the presentation will toggle between the different slaves If SuperVis...

Page 19: ...ng time limit This alarm can be displayed when the turbine is used with a WS4 ES water separator If displayed check the water separator to see why the pump has not succeeded in emptying the machine Air flow is too low If displayed the turbine is running with too much counterpressure Check the installation Mainboard connection failure Internal error If it remains please contact service technician P...

Page 20: ...e knobs of the filter hatch anti clockwise to open it Pull out the dirty filter and insert the replacement filter Close the hatch by turning the knobs clockwise 3 Reconnect power The cooling air filters shall be replaced regularly suitably for each new job In very dirty environments even more frequent replacements can be necessary 4 Turn the knob anti clockwise to remove the filter holder 5 Remove...

Page 21: ...pending on installation Drill further holes and connect additional hoses or whatever is appropriate and feasible to decrease the resistance and increase the flow The turbine makes noise does not sound the way it normally does Bearing in motor is worn and or damaged Please contact your retailer for repair The turbine has stopped does not start No mains power Built in overheating protection triggere...

Page 22: ...se dBA 3m approx 48 Voltage 230 VAC 50 Hz Rated power W 1100 Height x width x length mm 430 x 295 x 370 Weight kg 14 Noise level varies with installation CTR T4 ES Air volume m3 h Up to 300 continuously variable Pressure mbar Up to 260 continuously variable Noise dBA 3m approx 48 Voltage 230 VAC 50 Hz Rated power W 1800 Height x width x length mm 430 x 295 x 430 Weight kg 17 5 Noise level varies w...

Page 23: ...Interface Map for CTR A2ES CTR A4 ES and CTR A ES Top Menu ...

Page 24: ...Sublevels Info Statistics Info Info Info Reset Reset Info ...

Page 25: ...Select Change Change Reset Change Run Change Pressure Change View Functional test of the display This is to test that all pixels are active ...

Page 26: ...Create Activate Activate Deactivate OK Edit ...

Page 27: ...Info Change ...

Page 28: ...evelops manufactures sells and hires out high quality products for dealing with water damage moisture odours and radon We are market leaders and specialise in innovation within the industry Our products are compact effec tive ergonomic and energy efficient In emergency situations and during flooding Corroventa s customers have access to one of the largest rental parks in Europe We have sales offic...

Reviews: