36
P050 Multi-Input FOR Factory Setting: 02
P051 Multi-Input REV Factory Setting: 03
P052 Multi-Input RST Factory Setting: 10
P053 Multi-Input SPH Factory Setting: 17
P054 Multi-Input SPM Factory Setting: 18
P055 Multi-Input SPL Factory Setting: 19
Set Range: 00~32 Unit: no
00: Invalid: When the terminal is set for null, it can avoid faulse operation.
01: Run: It can be combined with other terminals to combine various control methods.
02: FWD Forward rotation
03: REV Reverse rotation
04: STOP
05: FWD/REV
06: JOG
07: Jog Forward rotation
08: Jog Reverse rotation
09: Emergency Stop: It can receive external emergency stop or other fault signals.
10: RST This terminal can be used to reset after the fault is removed.
12: Overheat of radiator or motor: This contact can be used to detect overheat of the radiator or
motor to protect the motor and inverter.
13: Externally Controlled Timer 1 start: When the contact is closed, the timer will start and begin to
count time. When the timer reaches the point the responding multi-outputs will act.
14: Externally Controlled Timer 2 start
17: High Speed: High, middle and low speed can compose three kinds of different operation patterns.
18: Middle Speed: In the three terminals the high-end signal has priority.
19: Low Speed: Determined by Frequency 3, 4.
20: Multi-speed 1 Multi-speed 1, 2, 3 can compose 7-Steps.
21: Multi-speed 2
22: Multi-speed 3
23: Acel/Decel Select 1: This terminal can be used to selcect the acel/decel time of the inverter.
24: Acel/Decel Select 2:
25: UP function: When this terminal switch acts the frequency will increase by one unit.
26: DOWN function: When this terminal switch acts the frequency will decrease by one unit.
27: Counter: When the terminal is set for the counter it can receive the pulse signal of ≤250HZ
and count the number.
28: Counter reset: the action of this contact can clear the present counting value.
29: Drawing start: When the contact is triggered the action of drawing will start.
31: Auto PLC reset suspend: This contact can be used to realize the function of suspending clear-
up of Auto PLC.
32: PID valid: PID becomes valid and working.
A. Using the three multi-function terminals to form the connection method of three-wire system for
the realization of switching FWD/REV, which is extentively applied in the case of switching