dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort
05-2018
936021
9
Floor guide
Glass
2.9.1
Align centerline of glass with centerline of floor
guide.
2.9.2
Be sure the glass is plumb.
2.9.3
Mark appropriate floor guide measurements.
2.9.4
DISENGAGE ANTI-JUMP.
2.9.5
TEMPORARILY REMOVE GLASS AND
ROLLERS FROM TRACK.
2.9.6
Pre-drill into mounting surface using a 5/16"
drill bit.
2.9.7
Secure floor guide anchor with included
fasteners.
Glass
X
Floor
guide
M50
X
1-1/4” - (T/2)
[31.5 - (T/2)]
Floor
guide
anchor
1-7/
16"
[36
]
13/
16"
[20
]
Wall
T
2.9
Install floor guide
Fig 6
2.10.1
SET GLASS AND ROLLERS BACK ONTO
TRACK.
2.10.2 Slide floor guide over floor guide anchor and
tighten with set screws.
2.10.3 Remove setting blocks.
NOTE: Be sure glass is centered in floor guide.
2.10.4 Adjust using set screws.
Floor
guide
Floor
guide
anchor
Glass
Set screws
Hex key size
M50
1.5mm
2.10
Install floor guide: continued
Fig 7