dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort
05-2018
936021
10
Height adjustment
2.11.1 Set height of glass door.
2.11.2 Using appropriate-size hex key, turn height
adjustment screw
CLOCKWISE
or
COUNTER-
CLOCKWISE
to raise or lower glass.
NOTE: Be sure glass is level during this adjustment.
2.11.3 Re-engage anti-jump by turning anti-jump
adjustment screw
CLOCKWISE
.
NOTE: Anti-jump should NOT touch track.
Door height
adjustment tolerance
M50
+5/32" [+4]
-3/32" [-2]
Glass
Floor
guide
3/8"
[10]
=
=
Hex key size
M50
2.5mm
Anti-jump
adjustment
screw
[0 < X < 1/32" (0.5)]
X
Height
adjustment
screw
2.11
Adjustment door height
Fig 8