background image

dormakaba MUTO M50 Ceiling Mount less Dormotion  
Installation Instructions

MUTO Comfort

05-2018

936021

8

Track

Anti-jump

2.7.1 

Place glass on setting blocks on floor for 
stability.

2.7.2 

Tip glass and rollers upward and rest rollers on 
track.

ENSURE ROLLERS AND TRACK ARE FREE OF DEBRIS.

Setting blocks

2.7 

Install glass/rollers in track

Fig 4 

2.8.1 

Temporarily engage anti-jump on roller carrier.

2.8.2 

Using appropriate-size ball-end hex key, turn 
adjustment screw 

CLOCKWISE

 to 

engage

 

anti-jump.

Hex key size

M50

2mm

Anti-

jump

Anti-jump 

adjustment 

screw

2.8 

Engaging anti-jump

Fig 5 

Rollers

Summary of Contents for Muto Comfort M50

Page 1: ...Muto Comfort M50 Ceiling mount less Dormotion Installation instructions 936021 05 2018 EN ...

Page 2: ...ir 3 1 1 8 Disposal 3 2 Installation instructions 4 2 1 Overall 4 2 2 Securing track to mounting surface 5 2 3 Door wall dimensions 6 2 4 Specifications technical data 6 2 5 Installing roller carriers on monolithic glass ONLY 7 2 6 Installing end stops 7 2 7 Install glass rollers in track 8 2 8 Engaging anti jump 8 2 9 Install floor guide 9 2 10 Install floor guide continued 9 2 11 Adjustment door...

Page 3: ...36 and ASTM C 1048 Secondary heat soaking processes are recommended but not required This applies to both tempered monolithic and tempered laminated glass Clamping area must be flat and uncoated no self cleaning coating Never use glass with conchoidal fractures and or damaged edges 1 1 5 Safety instructions Installation requires two people Only properly qualified and specially trained staff are au...

Page 4: ...ation Instructions MUTO Comfort 05 2018 936021 4 Overall 1 1 Cover 1 2 Brush strip 1 3 Track 1 4 End cap 2 1 Overall 2 Installation instructions 1 5 End stop 1 6 Cover clips 1 7 Roller carrier 1 8 Floor guide 1 1 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 5 1 4 1 7 1 6 ...

Page 5: ...n the interior of this surface Track mounting screws must fully penetrate the steel angle metal stud or at a minimum of 2 51 into wood blocking utilizing the predrilled holes in the MUTO track Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location 2 2 1 Ensure the track is properly level and secure it to...

Page 6: ... 1 3 16 30 1 3 16 30 clear opening height CH clear opening width CW Glass door Glass door panel DW 3 8 10 Bottom of glass to floor Back of track to center of mounting hole in track 1 25 Single Door M50 Ceiling mount Door leaf weight lbs kg 110lbs 50 Including weight of auxiliary hardware 2 3 Door wall dimensions 2 4 Specifications technical data ...

Page 7: ...SS LEADING IS SIDE CLOSEST TO LATCH CLOSED Secure Legend Closing edge of door Hex key size M50 3mm Back of Glass Back of Glass X Z 3 1 8 80 3 1 8 80 Glass gasket Roller carrier 2 5 Installing roller carriers on monolithic glass ONLY Fig 2 2 6 1 Slide end stops into each end of the track NOTE DO NOT FULLY TIGHTEN NOTE Exact location adjustments will be determined in Adjustment End Stop Location ste...

Page 8: ...ss and rollers upward and rest rollers on track ENSURE ROLLERS AND TRACK ARE FREE OF DEBRIS Setting blocks 2 7 Install glass rollers in track Fig 4 2 8 1 Temporarily engage anti jump on roller carrier 2 8 2 Using appropriate size ball end hex key turn adjustment screw CLOCKWISE to engage anti jump Hex key size M50 2mm Anti jump Anti jump adjustment screw 2 8 Engaging anti jump Fig 5 Rollers ...

Page 9: ...nto mounting surface using a 5 16 drill bit 2 9 7 Secure floor guide anchor with included fasteners Glass X Floor guide M50 X 1 1 4 T 2 31 5 T 2 Floor guide anchor 1 7 1 6 3 6 1 3 1 6 2 0 Wall T 2 9 Install floor guide Fig 6 2 10 1 SET GLASS AND ROLLERS BACK ONTO TRACK 2 10 2 Slide floor guide over floor guide anchor and tighten with set screws 2 10 3 Remove setting blocks NOTE Be sure glass is ce...

Page 10: ...ew CLOCKWISE or COUNTER CLOCKWISE to raise or lower glass NOTE Be sure glass is level during this adjustment 2 11 3 Re engage anti jump by turning anti jump adjustment screw CLOCKWISE NOTE Anti jump should NOT touch track Door height adjustment tolerance M50 5 32 4 3 32 2 Glass Floor guide 3 8 10 Hex key size M50 2 5mm Anti jump adjustment screw 0 X 1 32 0 5 X Height adjustment screw 2 11 Adjustme...

Page 11: ...ller carrier NOTE bi folding Be sure there is a 1 4 6 gap between the right and left hand sets 0mm END STOP LOCATION LEADING EDGE Bumper Edge of roller carrier End stop Door closed Door pull Jamb edge Glass edge max 1 3 16 30 Glass overlap on wall Door pull to jamb distance Verify with local jurisdiction Bumper Secure Bumper Secure Hex key size M50 2mm 2 5mm M50 torque 3 ft lbs 4 Nm Door opened 0m...

Page 12: ... clips Brush profile 2 13 1 Insert cover clips into track One clip per foot 2 13 2 Insert perpendicular to track and turn CLOCKWISE to snap into place 2 14 1 Measure and cut brush to appropriate length 2 14 2 Slide brush into track Cover clip Brush Track 2 13 Cover clips 2 14 Install brush profile Fig 11 Fig 12 ...

Page 13: ... Cover End caps 2 15 1 Secure cover to clips and snap into place NOTE Roll cover from the bottom upwards Ensure the bottom of the cover is supported by the groove in the cover clip 2 16 1 Snap end caps onto track End cap End cap Cover 2 15 Install cover 2 16 Install end caps Fig 13 Fig 14 Cover Cover clip ...

Page 14: ...www dormakaba com dormakaba USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...