1  About this manual

1.1  Information about the 

manual

This instruction is part of the product. The instruction 
comprises important instructions for safe operation. 
Therefore, the instruction must be carefully read 
before using the product. This instruction must be 
kept during the service life of the product and must 
be passed on with the product. This instruction 
describes the installation, startup, maintenance and 
disassembly of the slide rail system G‑EMF XEA. The 
text of the instruction is supported by figures in a 
separate figure part. The chapter numbers in the text 
can be found again top left in the figures in the figure 
part. There is not always a figure in the figure part to 
support a chapter in the text. 

1.2  Target groups

The installation, startup, maintenance and 
disassembly must only be carried out by skilled staff 
which has been authorized by dormakaba. The 
operation of the slide rail system may be carried out 
by any person who is mentally and physically able.

1.3  Provided documents

•  Installation manual
•  Data sheet about the use of arrest systems

1.4  Symbols and abbreviations 

used

1.4.1  Safety instructions

ATTENTION

This signal word indicates a situation of 
potential risk, which could lead to damage 
to property or the environment if not 
averted.

1.4.2  Further labeling

2.

1.

Step‑by‑step graphics

1

2

Position numbers of parts

The illustration shows the mounting 
DIN‑L on the hinge side. Mounting 
DIN‑R takes place mirror‑inverted.

Illustration shows mounting DIN‑R on 
the hinge side. Mounting DIN‑L takes 
place mirror‑inverted.

1.4.3  Tool symbols

Allen wrench,  
e.g. wrench size 3

1.5  Glossary

EMF 

Electromechanical locking device

RMZ 

Smoke detection panel

TS 

Door closer

2  Safety

2.1  Intended use

The catching device is used to keep open door leaves. 
The locking mechanism is used in conjunction with 
external RMZ to keep open fire and smoke protection 
closures. Fire and smoke protection closures must 
meet the building regulation requirements ‘’self‑
locking’’. The electromechanical locking device is no 
substitution for a door stop. The locking device is 
released manually or via an external RMZ.

2.2  Limitation of liability

The manufacturer does not assume liability for 
damages in the following events:
•  Nonobservance of this instruction.
•  A deviating application of the intended use.
•  The assignment of insufficiently skilled staff.
•  Unauthorized modifications.
•  Technical alterations.
•  The use of spare parts which are not authorized.

2.3  Prerequisites for the 

operation of catching devices

The use of catching devices is subject to special 
regulations by reason of official admission standards. 
These regulations refer in particular to the inspection, 
the continuing surveillance and the maintenance. 
Follow the details from the data sheet about the use 
of catching devices. Additional requirements apply for 
the use as fire and smoke protection closures in 
conjunction with the external RMZ and RM. A 
separate verification of suitability is required for the 
respective fire / smoke protection door.

2

G-EMF XEA

2017-10

dormakaba

WN 059411 45532

About this manual

Installation manual

Summary of Contents for G-EMF XEA

Page 1: ...ation of catching devices 2 3 Product description 3 3 1 EMF 3 3 2 Technical data 3 4 Installation 3 4 1 Prepare the mounting of the slide rail 3 4 2 Mount the slide rail 3 4 3 Mount the door closer 3 5 Start up 4 5 1 Set the fixture point 4 5 2 Set the release force 4 5 3 Mount the paneling 4 5 4 Check locking 4 6 Operating 4 6 1 Open and lock door 4 6 2 Close door 4 7 Dismounting recycling and di...

Page 2: ...nverted Illustration shows mounting DIN R on the hinge side Mounting DIN L takes place mirror inverted 1 4 3 Tool symbols Allen wrench e g wrench size 3 1 5 Glossary EMF Electromechanical locking device RMZ Smoke detection panel TS Door closer 2 Safety 2 1 Intended use The catching device is used to keep open door leaves The locking mechanism is used in conjunction with external RMZ to keep open f...

Page 3: ...xternal RMZ 4 Installation The mounting of the slide rail system takes place directly on the base of the door lintel or optionally with an additional mounting plate extras 4 1 Prepare the mounting of the slide rail The slide rail can be mounted in two different options Option A Mounting on the hinge side Option B Mounting on the opposite hinge side 1 Prepare the power supply 24 V 48 V DC from the ...

Page 4: ...width and the selected size of the closing contact According to the DIN EN 1155 the release force must not be less than 40 Nm at a door opening angle of 90 and not more than 120 Nm 1 Set the release force 2 Control the release force 5 3 Mount the paneling 1 Attach the end caps 2 Mount the paneling of the glide rail 5 4 Check locking 1 Open the door leaf and lock it 2 Cut off power supply The door ...

Reviews: