5  Start up

5.1  Set the fixture point

ATTENTION

Risk of cable damage

While setting the fixture points cables might 
be damaged.
•  Pay attention not to jam the connecting 

cables.

1. 

Feed the power supply (24 V/48 V DC).

2. 

Open the fixed leaf until it clicks.

3. 

Unbolt the screws of the locking unit(s).

4. 

Open the door leaves to the desired hold open 
bracket.  
If the EMF is pushed to the end of the slide rail, 
the cable clips must be removed.

5. 

Unbolt the screws of the locking unit(s).

6. 

Place the door stop into the position of the fixture 
points selected.

5.2  Set the release force

ATTENTION

Risk of damage to the catching device

 

Setting a release force too high may result 
in damage to the door hinges and the 
fastening elements of the door closing 
system. 
•  Set the release force depending on the 

door width and the selected size of the 
closing contact. 

•  According to the DIN EN 1155 the release 

force must not be less than 40 Nm at a 
door opening angle of 90° and not more 
than 120 Nm.

1. 

Set the release force.

2. 

Control the release force.

5.3  Mount the paneling

1. 

Attach the end caps.

2. 

Mount the paneling of the glide rail.

5.4  Check locking

1. 

Open the door leaf and lock it.

2. 

Cut off power supply.

 

‣ The door leaf is released and closes.

6  Operating

6.1  Open and lock door

1. 

Open door leaves to the fixture point.

 

‣ The door leaves remain standing after letting 

go.

6.2  Close door

1. 

Press shut the door leaf or press the optional 
manual release button. 

 

‣ The door leaf is released and closes.

7  Dismounting, 

recycling and 

disposal

Dismantling is the same procedure in reverse and 
must be carried out by qualified personnel. 
The product must be disposed of environmentally 
sound. Electro‑technical parts and batteries must not 
be disposed of as household waste. Dispose of 
electro‑technical parts and batteries in the arranged 
acceptance and collection points.

Tr

anslation o

the original manual, subjec

to change 

witho

ut no

tic

e

Summary of Contents for G-EMF XEA

Page 1: ...ation of catching devices 2 3 Product description 3 3 1 EMF 3 3 2 Technical data 3 4 Installation 3 4 1 Prepare the mounting of the slide rail 3 4 2 Mount the slide rail 3 4 3 Mount the door closer 3 5 Start up 4 5 1 Set the fixture point 4 5 2 Set the release force 4 5 3 Mount the paneling 4 5 4 Check locking 4 6 Operating 4 6 1 Open and lock door 4 6 2 Close door 4 7 Dismounting recycling and di...

Page 2: ...nverted Illustration shows mounting DIN R on the hinge side Mounting DIN L takes place mirror inverted 1 4 3 Tool symbols Allen wrench e g wrench size 3 1 5 Glossary EMF Electromechanical locking device RMZ Smoke detection panel TS Door closer 2 Safety 2 1 Intended use The catching device is used to keep open door leaves The locking mechanism is used in conjunction with external RMZ to keep open f...

Page 3: ...xternal RMZ 4 Installation The mounting of the slide rail system takes place directly on the base of the door lintel or optionally with an additional mounting plate extras 4 1 Prepare the mounting of the slide rail The slide rail can be mounted in two different options Option A Mounting on the hinge side Option B Mounting on the opposite hinge side 1 Prepare the power supply 24 V 48 V DC from the ...

Page 4: ...width and the selected size of the closing contact According to the DIN EN 1155 the release force must not be less than 40 Nm at a door opening angle of 90 and not more than 120 Nm 1 Set the release force 2 Control the release force 5 3 Mount the paneling 1 Attach the end caps 2 Mount the paneling of the glide rail 5 4 Check locking 1 Open the door leaf and lock it 2 Cut off power supply The door ...

Reviews: