4.5.2.7 TouchGo sensitivity
In this menu, you can adjust the sensitivity. The sensitivity can thus be reduced within an
interference-free environment, or increased to improve reading properties.
The menu is only displayed on the programmer if TouchGo actuators are recognised.
Procedure:
1.
Use the programming cable to connect the programmer and actuator (E110/E310).
2.
Open the 'Settings' menu.
3.
Open the 'Actuator' menu.
4.
Log the master medium in to the actuator.
5.
Choose the 'Actuator/TouchGo selectivity' sub-menu.
6.
Press the ENTER key.
7.
Select a value between 1 and 6.
Note:
Value 1 corresponds to the lowest sensitivity. The factory setting is 3.
8. Press the ENTER key.
ð
The selection is saved.
4.5.2.8 INI reset
1.
Open the 'Settings' menu.
2.
Open the 'Actuator' menu.
3.
Log the master medium in to the actuator.
4.
Connect the programmer to the actuator.
5.
Choose the 'INI reset' sub-menu.
6.
Press the ENTER key.
7.
Select "Yes".
ð
INI reset is executed.
Operation
User Manual
23
- 06/2021
dormakaba Programmer 1460