4
The monitor is fused internally, however some installers would still prefer to install
an inline fuse for precautions. We suggest an optional 2-amp fast blow fuse be used for
this purpose.
II. SETUP AND INSTALLATION
The first time the monitor is powered up the display will show
NSP
.
This is saying that
there are
No Sensors Programmed
to the monitor. It could be that the sensors that
were programmed to the monitor have not reported in to the monitor in order to lock the
sensors into the memory. If this is the case it could take up to 6 minutes for this to
happen. If this is the first time you have attempted to install the system and the sensors
have not been programmed into the monitor, the system will need to be programmed per
the following section.
PROG
Used to enter the program modes.
Also used to silence alarms.
SET
Used to lock in selections
during programming. Used to turn
on and off the backlight.
(4) Arrow buttons are used to
Navigate the screen and select
values in the program mode
2. Programming the Monitor
For the monitor to function effortlessly, the user must install the correct data. The information
input to the monitor will allow the monitor to recognize the sensors and wheel positions as well as
the baseline pressures for all tires. This is done in the following steps.
Do not install sensors until all programming is completed and you have returned to the
normal operation mode.