DOOSAN INFRACORE 27/36
27
-When there is not pallet to load in the
destination station, this alarm is occurred.
and if pallet is not, modify pallet information data
of station.
121
To Cycle Target Data Error
- When there is pallet to unload in the
destination station, this alarm is occurred.
- confirm if there is pallet in destination station,
and if pallet is not, modify pallet information data
of station.
122
From Setup-1 Condition Error
- When there is not pallet to load in the setup
station#1, this alarm is occurred.
- confirm if there is pallet in the setup station#1.
123
From Setup-2 Condition Error
- When there is not pallet to load in the setup
station#2, this alarm is occurred.
- confirm if there is pallet in the setup station#2.
124
From MC-1 Condition Error
- When there is not pallet to load on the
machine#1 s APC, this alarm is occurred.
- confirm if there is pallet on the machine#1 s
APC.
125
From MC-2 Condition Error
- When there is not pallet to load on the
machine#2 s APC, this alarm is occurred.
- confirm if there is pallet on the machine#2 s
APC.
126
From MC-3 Condition Error
- When there is not pallet to load on the
machine#3 s APC, this alarm is occurred.
- confirm if there is pallet on the machine#3 s
APC.
200
MC-1 Not Ready
-DP-Slave is not ready
Check Machining Center#1 s DP-Slave status and
cable.
210
MC-2 Not Ready
- DP-Slave is not ready
Check Machining Center#2 s DP-Slave status and
cable.
220
MC-3 Not Ready
- DP-Slave is not ready
Check Machining Center#3 s DP-Slave status and
cable.