Maintenance Section
-174-
Every 1000 Service Hours or 6 Months
You must read and understand the warnings and instructions contained in the Safety section of this manual, before
performing any operation or maintenance procedures.
Fuel Filters - Change
Diesel Engine
Park the lift truck with the forks lowered, parking brake
applied, transmission in neutral, engine stopped and
cool.
1. Raise the hood and seat assembly. Make sure the
hood support latch is engaged in the bracket.
WARNING
Fuel leaked or spilled onto hot surfaces or electrical
components can cause a fire.
Turn the disconnect switch OFF or disconnect the
battery when changing fuel filters.
2. Loosen the plug (1) and remove cartridge (12) from
head.
3. Fill up clean fuel to the new cartridge.
4. Replace the rubber packing and smear clean fuel to
the rubber packing.
5. Install new cartridge and remove an air in the filter
with a feed pump.
Air Intake System - Change
Changing Primary Element
See topic, “Air Intake System - Check, Clean” in “Every
250 Service Hours or Monthly”.
Changing Secondary Element
Replace the secondary element after the primary
element has been cleaned three times or yearly.
1. Remove the primary air cleaner element. See topic
“Servicing Filter Element”. Clean the inside of the air
cleaner housing and cover.
2. Remove the secondary element. Inspect the gasket
between the air cleaner housing and the engine
inlet. Replace the gasket if it is damaged.
NOTICE
Always replace the secondary element. Do not
attempt to reuse it by cleaning.
3. Install a new secondary element. Install a new or
cleaned primary element. Install the cover. Tighten
the latches.
4. Start the engine and observe the air cleaner service
indicator. If the indicator shows RED after installing
a new secondary element and a cleaned primary
(outer) element, replace the cleaned primary filter
with a new element.
5. Stop the engine. Close the hood and seat assembly.