4
SAFETY INSTRUCTIONS
Check if the gate conforms to the standards EN12604 and EN 12605 (see documentation accompanying the gate). For
countries, which are not EC members, the above mentioned requirements shall be met in order to obtain an appropriate
safety level.
Mechanical units of the gate shall conform to the standards EN12604 and EN 12605.
Prior to installation, check that the location of operator installation is suitable by its climatic conditions to technical
specifications of the operator.
•
Do not install the operator in premises containing quick inflammable substances or other dangerous environments as it can
cause explosion or fire.
•
During assembly, installation and adjustment use tools specified in section “Tools” of this manual.
•
When performing operation at height, use a stable support.
•
The operator is not intended for installation at a height exceeding 2,5 m.
•
When drilling holes, use protection for hands and eyes.
•
For fastening of the item, use hardware supplied with the operator or other analogous one.
•
Disconnect the supply when cleaning or other maintenance is being carried out, if the appliance is automatically controlled.
•
If the operator is installed on the gate with a wicket door an additional safety device should be used to prevent operator
activation when the wicket door is open.
•
Ensure that entrapment between the driven part and the surrounding fixed parts due to the opening movement of the driven
part is avoided.
•
It is highly recommended to use DoorHan optional equipment as the accessories produced by other manufacturers can
damage the automated system.
•
DoorHan is not responsible for unstable work of the automatic system when using safety devices and accessories, which
are produced by other manufactures without agreement with DoorHan.
•
Never leave the electric motors in released condition. This may cause uncontrolled movement of the gate leaves and,
consequently, their breakdown.
•
Do not use the operator if it needs repair or adjustment as installation defects or unbalanced door can cause injury.
•
DoorHan shall not be held liable in case of improper installation of the item and damage arisen during operation.
•
Since the operator does not have a power cord with a plug it shall be connected to the mains supply via automatic switch
with a minimal distance of 3 mm between the neighboring contacts. It is recommended to use a 6А double -pole circuit-
breaker.
•
Be sure there are no obstructions to door travel.
•
Do not make any changes in the automatic system not specified in this manual.
•
Remove package of the item and dispose of it. Keep the package materials away from children.
•
Always keep remote controls out of reach of children. Never permit children to operate or play with garage door control
push buttons or remote controls.
•
No one should cross the pass of the moving door.
•
The content of the manual shall not be basis for any claim.
•
The manufacturer reserves the right to modify the design of the product described in this manual without preliminary
notice.
•
After installation, ensure that the mechanism is properly adjusted and that the protection system and any manual release
function correctly.
WARNING!
For safe and correct operation of the operator put stoppers to limit the gate wing travel.
•
The Installation and configuration of the actuator must only be carried out by qualified specialists.
•
After installing the drive, test force according to standards EN 12445 and EN 12453.