background image

3

General InfOrMatIOn

specifications

Units

Supply voltage

220–240 V/50 Hz

Rated power

150 W

consumption current

1,8 A

Rod speed

1,8 cm/s

Maximal wing length

2,5 m

Maximal wing weight

350 kg

Thermal protection

150°

protection rating

Ip 44

use intensity

50 %

Operating temperature range

–20…+55 °c

1.2.  operator paCkage

upon receiving the operator, unpack it and inspect carefully. If any signs of damage are observed, please contact your supplier.

The operator components included in the standard package are listed in the following table.

* При ширине створки 2 м.

#

name

Quantity

1

Operator

2

2

control block unit

1

3

Release

2

4

Rear fastening bracket

2

5

Front fastening bracket

2

6

Set of fasteners

1

7

user manual

1

1.1.  teChniCal speCifiCations

2.  safety instrUCtions

Warning!

 important safety instrUCtions! It is important for the safety of persons to follow safety instructions. 

Save these instructions.

1.   general information

The electromechanical linear operator Swing-2500 is intended for automation of a street double-leaf swinging gate with a load-

bearing structure. 

The body of the operator, which consists of two silumin parts, houses a motor, a reducer and a lead screw.
A self-blocking system, consisting of a worm gear and a planetary gearbox blocks the gate leaves, if the motor is off. The easy-

to-use and safe release system allows the gate leaves to be opened/closed manually, in case of a power cut or control unit failure. 
Operation of the automatic system is controlled from a remote control unit in a shockproof hermetic case.

 

 Follow all instructions since incorrect installation can lead to severe injury.

 

 Swing-2500 was designed for automation of a street double leaf swinging gate with a load bearing structure. Do not use 
the operator for other than intended purposes.

 

 DoorHan shall not be held responsible in case of injury caused by misuse of the product.

 

 prior to installation make sure that the gate moves smoothly.

 

 Installation must be performed in accordance with the standards EN12453 and EN 12445. For countries, which are not 
Ec members, these requirements are to be met.

Summary of Contents for Swing-2500

Page 1: ...r SWING 2500 DoorHan 2014 Installation and Operating Manual 2 3 3 5 5 9 9 9 contents General Information Safety instructions Operator unit Installation emergency Release Operation maintenance Troubles...

Page 2: ...ecifications 3 1 2 Operator package 3 2 Safety instructions 3 3 Operator Unit 5 4 INSTALLATION 5 4 1 Tools 5 4 2 Installation layout 6 4 3 Installation dimensions 6 4 4 Operator installation 7 5 EMERG...

Page 3: ...ator Swing 2500 is intended for automation of a street double leaf swinging gate with a load bearing structure The body of the operator which consists of two silumin parts houses a motor a reducer and...

Page 4: ...ible for unstable work of the automatic system when using safety devices and accessories which are produced by other manufactures without agreement with DoorHan Never leave the electric motors in rele...

Page 5: ...d and cross screwdrivers 3 Set of drills for metal 4 Set of drills for concrete 5 Pliers 6 Hacksaw for metal 7 Electric drill 8 Tape measure folding rule 1 2 3 4 5 1 Motor 2 Power cable 3 Rear fasteni...

Page 6: ...es and moving parts of the door In case of supply cable damage use the suitable type of the cable Cables needed for installation of Swing 2500 operator and accessories if available Cable 2 0 5 mm2 pho...

Page 7: ...lts should be screwed between the bricks When fastening to a concrete pole use anchor bolts as shown in the picture below 4 4 operator installation warning Before installation make sure that the gate...

Page 8: ...opening parameters and is adjusted during installation Fastening angle of rear bracket 98 mm 90 mm 95 mm 78 mm 68 mm 40 mm 28 mm Fastening angle of front bracket 158 mm 145 mm 55 mm 60 mm 155 mm 60 m...

Page 9: ...usted and safety devices are in good working condition In case of power failure you may need to restore operator s settings Once the power supply is restored check the automatic system for proper oper...

Page 10: ...Notes...

Page 11: ...Notes...

Page 12: ...our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Rep...

Reviews: