background image

2

CONTENTS

CONTENTS

1.  GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
 

1.1.  Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

 

1.2.  Operator package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

 

1.3.  Track  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2.  SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.  OPERATOR UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.  OPERATOR INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
 

4.1.  Tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

 

4.2.  Requirments to door installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

 

4.3.  Connection of operator and guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

 

4.4.  TRACK INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5.  ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
 

5.1.  SE-500 model  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

 

5.2.  SE-DIY-500 model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

6.  MANUAL OPENING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.  MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
8.  TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

1.  GENERAL INFORMATION

The Sectional-500/DIY-500 electromechanical chain operator is designed for automation of residential sectional doors.
It  consists  of  a  mechanical  gear  and  an  electric  engine  with  a  built-in  control  unit.  The  gear  and  the  electric  engine  are 

incorporated into a housing.

It  consists  of  an  electromechanical  motor  reducer,  an  electronic  control  unit  and  an  illuminating  lamp,  incorporated  into 

a housing. The electric operator is easily secured on a track and mounted to the ceiling, opening of the doors is carried out by 
means of a chain/belt gear. The self-locking operator gear ensures mechanical interlocking of the doors, if engine is not functioning, 
but in the absence of electric power the manual emergency release allows you to open and to close the doors manually.

For maximum safety, the control unit has force protection.
Besides, optionally, the operator can be equipped by electronic protective sensors, which stop the doors closing, if there are 

obstacles or people within the operating range of automatic system.

Summary of Contents for Sectional-500

Page 1: ...DoorHan 2013 Installation and Operating Manual 2 2 4 5 6 8 13 13 14 CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION ELECTRICAL CONNECTIONS MANUAL OPENING MAINTENAN...

Page 2: ...ilt in control unit The gear and the electric engine are incorporated into a housing It consists of an electromechanical motor reducer an electronic control unit and an illuminating lamp incorporated...

Page 3: ...tity 1 Electric operator 1 6 Guide fastening bracket 1 2 Operating manual 1 7 Headroom bracket 1 3 Guide 1 8 Straight arm fastening bracket 1 4 Curved arm 1 9 Slotted bushing 1 5 U shaped bracket 2 10...

Page 4: ...safety device which prevents the operator activation when the door is open Make sure that there will not be trapping of articles between movable and fixed elements of the operator when the doors move...

Page 5: ...74 100 WARNING RISK OF INJURY Have a qualified technician lay the cables 230 V AC The cables must be laid in protective corrugated tubes In case of supply cable damage use the suitable type of the cab...

Page 6: ...rated Make sure that minimal clearance between the ceiling and the top point when the door is moving is not less than 45 mm pic 1 Check that the door leaf top roller is in the horizontal part of the g...

Page 7: ...k 3 and the lintel mounting bracket by means of a track fixation bolt 4 fig 5 3 5 You should install a U shaped bracket 5 on the track approximately at a distance 2 3 L and attach it to the ceiling fi...

Page 8: ...z Operating logics Automatic Semi automatic Connectors Open button Safety devices Lamp turn on time 3 min Fuse type Quick cutoff fuse 230 V 2 5 SR F2 5A 5 ELECTRICAL CONNECTIONS 5 1 SE 500 MODEL Contr...

Page 9: ...sing the select the menu 1 press P and hold it unless the 0 appears on the display The operator has a default setting of sensitivity level 4 Usually the user doesn t need to change this setting AUTOMA...

Page 10: ...value 0 off 1 on Press P Press P in order to store 1 You should press and hold down the button S until the indicator dot at the bottom of the display lights up Release the button 2 Select the button...

Page 11: ...control frequency MHz 433 Operating logics Automatic Semi automatic Connectors Open button Safety devices Lamp turn on time min 3 Fuse type Quick cutoff fuse 230 V 2 5 SR F2 5 A ontrol block specifica...

Page 12: ...button By pressing and set the leaf into the required upper position R P 1 2 3 Press P for going into the next mode Indicator 2 will flash By pressing and set the leaf into the required lower positio...

Page 13: ...cally only after the carriage meshes with the chain support 7 MAINTENANCE The Sectional 500 DIY 500 automatic system does not require any special servicing Repairs may be carried out only by a qualifi...

Page 14: ...k Programming error Reprogram the door Noise when operator runs Chain is not properly lubricated Lubricate the chain Chain makes noise and rubs against the guide Chain has stretched Tighten the chain...

Page 15: ...Y PROCEDURE Unpack a guide and inspect it Make sure that the guide is not damaged If you have found any damages please contact the supplier fig 1 1 2 Place structure elements 1 2 3 along one line as i...

Page 16: ...is pressed down ATTENTION During start up and slowdown stages in case of big doors the belt can transiently slack in relation to a tire section However this phenomenon does not have any negative cons...

Page 17: ...inspect it Make sure that the guide is not damaged If you have found any damages please contact the supplier 2 Disassemble a chain tensioner mechanism pos 1 fig 1 3 Unfasten screws of a sprocket hold...

Page 18: ...PPENDIX 2 Figure 4 Figure 5 4 5 Disassemble a support pos 4 into two parts fig 4 6 Cut the guide and shorten the chain to the required dimensions fig 5 7 After cutting assemble the guide in reverse or...