12
Operator programming
Open the lamp housing to reach key panel.
“Р” — programming key
“R” — remote control storing key
“+” and “–” — setting keys
Indicators “1”, “2”, “3” — show the settings
OPERATOR KEY PANEL
PREPARATION
Block the carriage.
If programming has not been completed, the settings will not be stored. If there is a mistake in one of the settings, you can
turn off power and reprogram.
UPPER AND LOWER DOOR POSITIONS
R
P
+
–
1 2 3
R
P
+
–
1 2 3
Press and hold down
the button “P” for about
5 seconds
Press and hold down the buttons “P” and “R” simultaneously, indicator 3 will flash.
By pressing “+” and “–”, set the force level:
• 1 flash means the first force level;
• 2 flashes mean the second force level;
• 3 flashes mean the third force level.
Press the button “P” in order to store and to exit the force menu, otherwise you will automatically exit the setting mode
in 15 seconds. The settings will be stored by default.
Indicator “1” will flash.
Release the button. By
pressing “+” and “–”, set the
leaf into the required upper
position
R
P
+
–
1 2 3
Press “P” for going into the
next mode. Indicator “2”
will flash. By pressing “+”
and “–”, set the leaf into the
required lower position
R
P
+
–
1
3
2
R
P
+
–
2 3
1
After the doors are open,
indicator “2” will flash and
the doors will automatically
close. LED lamp will light
up, this means the end of
programming
Press “P”. Indicator “1”
will flash. The doors will
automatically open
After that programming may be completed.
AUTOMATIC CLOSING SETUP
FORCE SETTING
R
P
+
–
1 2 3
R
P
+
–
1 2 3
R
P
+
–
1 2 3
R
P
+
–
1 2 3
R
P
+
–
1 2 3
Open the door. Press and
hold the “+”. Indicators “1”,
“2”, “3” will start blinking.
Automatic closing is switched
off. Release the “+”
Use the “+” to choose one of
the automatic closing modes.
Press the “+” one time to
choose automatic closing in
30 sec, indicator “1” will glow
steadily
Press the “+” twice to choose
automatic closing in 60 sec,
indicator “2” will glow steadily
Press the “+” three times to
choose automatic closing in
90 sec, indicator “3” will glow
steadily
Wait for the indicators to go out and LED-lamp to light to exit the programming menu.
ELECTRICAL CONNECTIONS