Installation, Operation and Maintenance manual
34
WSO Flex
OPERATION SCHEDULE
To ensure a good performance of your mist collector, follow the check points below
according to the time table.
No. Checkpoint
Type of control
Recommended action
Day
Weeks
2
4
8
26
1
Fan set
Excessive noise
See trouble shooting guide
•
2
Clean air
chamber
Emission: oil mist emission
over in clean air chamber
See trouble shooting guide
•
3
Exhaust
Leakage at the exhaust
Check third stage filter
element and HEPA filter (if
applicable) for positive
gasket seals
•
4
Controller
Controller is giving alarm
See trouble shooting guide
•
5
Door
Visual check gaskets
Replace gaskets if
necessary
•
6
Connecting
ducts
Check for leakage
Repair if necessary
•
7
Mist collector Check damage, strength
and corrosion
Repair or replace if
necessary
•
8
Filter element Preventive replacement of
all filter elements
Unless otherwise specified in the scope of delivery
every 2 years.