Installation, Operation and Maintenance manual
14
WSO Flex
b. Adjustable mounting stand (only for WSO Flex-MMA)
An adjustable mounting stand is available for machines with no mounting surface
and for machines, which need to be totally isolated from vibration.
1. Use M10 anchor bolts to fasten the mounting stand to the floor. The anchor
bolts should extend 40 mm above the floor.
Use a crane or fork truck to lift and hold up the unit while installing the mounting
stand.
The mounting stand must be anchored to the floor before it is assembled to
the mist collector.
Level the mounting stand before securing anchor bolts.
2. Adjust the mounting stand by loosening the four locking bolts on the upper part
of the stand. Slide this section up to obtain the required height. Tighten bolts to
secure the stand in place.
Do not adjust the stand over a height of 2590 mm.
3. Position the unit over the stand and align the holes of the top plate of the
mounting stand with the studs.
4. Lower the unit onto the mounting stand. Use hardware shipped loose (nuts
and washers) to fasten the top plate of the mounting stand to the unit.
5. Before removing the lifting gear, re-check the hardware for tightness.
Make certain all nuts are tightened securely.