background image

- 1 - 

                                                                                   

               

            

Process enclosure, extract offtake(s), hose/ducting and extract/filtration unit.

          

          

Inspection and Maintenance Record 

1.     Daily inspection 
 

Inspection of the process to ensure extract devices/nozzles/enclosures/hoses are in place and correctly  
positioned.  Examination of the extractor to ensure it is running. This to be carried out by the operator. Daily 
inspection not recorded. 

 
2.    Weekly Inspection 

 

 

Weekly inspection by supervisor of physical condition of extract devices/nozzles/enclosures/hoses and 
extraction unit for damage, change (parts added or removed) and correct operation etc. Check also that daily 
inspections have been completed. Tick boxes to confirm system ok / change. Add details of any changes. 
Report changes to Engineering Manager. Record any remedial actions taken. 

 

Week 
number 

Date 

System 

ok 

System 
Change 

Details of change / repairs etc 

Initial 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 

 

 

 

 

 

11 

 

 

 

 

 

12 

 

 

 

 

 

13 

 

 

 

 

 

14 

 

 

 

 

 

15 

 

 

 

 

 

16 

 

 

 

 

 

17 

 

 

 

 

 

18 

 

 

 

 

 

19 

 

 

 

 

 

20 

 

 

 

 

 

21 

 

 

 

 

 

22 

 

 

 

 

 

23 

 

 

 

 

 

24 

 

 

 

 

 

25 

 

 

 

 

 

26 

 

 

 

 

 

Summary of Contents for BOFA AD 350

Page 1: ...VER 3 0 01 2020 AD 350 USER MANUAL...

Page 2: ...anel 1 01 02 Important safety notes Safety labels 2 01 Unpacking and unit placement 3 01 Turning extractor on adjusting airflow 5 01 02 Cleaning the unit Filter replacement 6 Consumable spares filter...

Page 3: ...Overview Control Panel Feet Clips Handles 01 1...

Page 4: ...Overview Air Inlet Mains Inlet Signal Cable Inlet Air Outlet Motor Cooling ON OFF Switch 02 1...

Page 5: ...Overview Flow Adjustment Company Branding Filter Blocked Filter 75 full System Running Clean VOC Alarm 03 1...

Page 6: ...supply before removing the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters w...

Page 7: ...t the extraction unit including Company name Address Contact number Extractor model Unit serial number Operating voltage range Maximum current load Operating frequency Year of Manufacture Relevant app...

Page 8: ...gases or with particulates which can be pyrophoric can spontaneously ignite without implementation of additional precautions It is essential that nozzles or other extraction fume capture devices and h...

Page 9: ...0 mm space is available around any vented panels on the extractor to ensure adequate airflow 2 Check the filter is located in its correct position before replacing the lid and securing the clips Cauti...

Page 10: ...uld be kept to a minimum where possible to prevent the fume being blown away from the nozzle High speed lines may need bigger scoops or nozzles both sides of the product because of the turbulence caus...

Page 11: ...replaced by a BOFA engineer as an electrical safety test may be required after replacement The unit MUST be connected to a properly earthed outlet If your system was ordered with any optional extras p...

Page 12: ...ther DC voltage input or the Volt free input The override feature can be toggled On Off by a switch mounted on the internal motor access panel see below for switch location Switch in On position In th...

Page 13: ...correct flow is maintained to compensate for any loss in performance caused by the added restriction of the partially blocked filters The extractor and all pipe work must be fully installed and conne...

Page 14: ...e of unauthorised replacement filters may result in a potentially dangerous situation and or damage to the extractor unit and will invalidate the manufacturer s warranty Cleaning the unit The powder c...

Page 15: ...e detailed below 1 Isolate the electrical supply to the extractor 2 Undo the two clips on the sides of the unit and remove the motor section using the two handles on the sides of the lid 3 Lift the fi...

Page 16: ...Date Engineer Combined Filter Date Engineer Filter disposal The combined filter is manufactured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method o...

Page 17: ...E UL cUL Size Metric mm Imperial inches Height 590 23 2 Depth 465 18 3 Width 405 15 9 Filters Filter Type Surface area Efficiency Pre Filter 6m2 95 0 9 microns HEPA Filter Combined filter 2 1 m2 99 99...

Page 18: ...Dorset BH17 7DU UK Tel 44 0 1202 699 444 Email sales bofa co uk German Office Sudring 62 D 21465 Wentorf bei Hamburg Germany Tel 49 0 40 739 3735 15 Email vertrieb bofa co uk BOFA Americas Inc 303 S...

Page 19: ......

Page 20: ...ocal Exhaust Ventilation Systems Company System Designation System Installation Date Designated Person Inspection and Maintenance Schedules 1 Daily checks 2 Weekly inspection of process enclosure extr...

Page 21: ...not recorded 2 Weekly Inspection Weekly inspection by supervisor of physical condition of extract devices nozzles enclosures hoses and extraction unit for damage change parts added or removed and corr...

Page 22: ...s and extraction unit for damage change parts added or removed and correct operation etc Check also that daily inspections have been completed Tick boxes to confirm system ok change Add details of any...

Page 23: ...ges to Engineering Manager Record any remedial actions taken Month number Date System ok System Change Details of change repairs etc Initial 1 2 3 4 5 6 7 8 9 10 11 12 4 Yearly Inspection Annual servi...

Reviews: