background image

Donaldson Company, Inc.

2

The Safety Alert Symbol indicates a hazardous situation which, if not avoided could 

result in death or serious injury. Obey all safety messages following this symbol to 

avoid possible injury or death. The possible hazards are explained in the associated 

text messages.

NOTICE indicates a potential situation or practice which is not expected to 

result in personal injury, but which if not avoided, may result in damage to 

equipment.

This manual has been supplied to assist with the installation, operation and maintenance for 

the collector purchased. Please read the manual before installing, operating, or performing 

maintenance on the collector as it contains specific precautions for worker safety. It is the 

owner’s responsibility to ensure that this manual is available for use by installers, operators and 

maintenance personnel that will be working with this collector. This manual is the property of the 

owner and should be left with the collector when installation has been completed. DO NOT operate 

this collector until you have read and understood the instructions and warnings located in the 

installation and operation manual.
For additional copies of this manual, contact Donaldson Torit.

IMPORTANT NOTES

Summary of Contents for RP Baghouse

Page 1: ...ecific precautions related to worker safety The hazard alert image denotes safety related instructions and warnings in this manual DO NOT install operate or perform maintenance on this collector until...

Page 2: ...operation and maintenance for the collector purchased Please read the manual before installing operating or performing maintenance on the collector as it contains specific precautions for worker safe...

Page 3: ...nlet Scroll Installation 25 High Inlet Installation 25 Platform and Ladder Installation 26 Cleaning Mechanism Assembly and Adjustment 27 PD Pump 29 Electrical Wiring 30 Perfect Pulse Controller Instal...

Page 4: ...ould comply with applicable codes and standards related to combustible dust Electrical installation must be performed by a qualified electrician This equipment is not designed to support site ducts pi...

Page 5: ...for the fitness of a mitigation strategy or product for a particular installation or application The process owner s final selection of dust collectors and risk mitigation strategies should be based...

Page 6: ...nd into the hopper This flow path reduces abrasion and assists the cleaning system by supporting an airflow pattern that encourages the dislodged dust pulsed off the filters to move downward into the...

Page 7: ...e disposed of via bin pneumatic conveyor screw conveyor or other means A rotary airlock is typically used to isolate the dust collection system from the dust disposal system Hopper Transition A transi...

Page 8: ...nlet As air enters it goes through a preseparation stage and then airflow straightening before it reaches the filters This allows the majority of the dust to drop out into the hopper and the airflow t...

Page 9: ...ensure proper pulse alignment and proper timing between pulses Cleaning Logic Using signals from the Sensor Switch and Target the Cleaning Logic Controller sets the time delay between pulses and adjus...

Page 10: ...e setpoints Optional RP Control Panels These options cover the sequencing of the related motors They also provide a HMI Interface Optional Control Panels PerfectPulse Cleaning System RP Controller RP...

Page 11: ...ic conveying ready valves and high clearance valves for tough to handle dusts Screw Conveyor Can be mounted directly to the hopper outlet with the addition of an RAL at the discharge Useful for loadin...

Page 12: ...t Operation During normal operation of an RP Baghouse with a tangential inlet dust laden air enters the dirty air inlet The tangential inlet induces a cyclonic action which pre seperates the majority...

Page 13: ...mp clean air outlet pleated filter access door pleated filter EvenFlow baffles helix hopper pleated filter hopper clean air outlet high body inlet pleated filter access door PerfectPulse cleaning syst...

Page 14: ...blower Shut Down 1 Shut off main blower Slowly ramping down airflow will allow accumulated dust to drop into the hopper gradually while the collector continues cleaning An abrupt reduction in airflow...

Page 15: ...ve chain Clean and properly tensioned PD pump drive Belts are intact and don t squeal Arm gearbox oil Gearbox oil level is at the proper level and not excessively dirty Explosion vents Vents are intac...

Page 16: ...vier than they appear Use appropriate lifting methods to avoid personal injury and or property damage Turn power off and lock out all power before performing service or maintenance work Do not operate...

Page 17: ...RP_RPH Baghouse 17 4 Once released the filter can be removed and disposed of properly 5 Slowly lower the filter through the tubesheet hole 6 Gently seat the filter flange against the tubesheet...

Page 18: ...he insert and replace if wear or damage are noted 8 Tip one side of the insert into the filter opening 9 Push down on the other side of the insert to seat it against the filter flange 10 Once all part...

Page 19: ...he dislodged portion The insert may need to be taken out and put back in 12 If the filter is not seated completely against the tubesheet see below the insert will need to be taken out and the filter p...

Page 20: ...installed and properly sealed Damper control not adjusted properly Check airflow in duct Adjust damper control until proper airflow is achieved and the blower motor s amp draw is within the manufactu...

Page 21: ...voltmeter check the PLC supply voltage Correct any power supply issues found If the proper power is supplied and the pulse should be active and still no signal output to the solenoid is present replac...

Page 22: ...22 Donaldson Company Inc Appendix A Installation...

Page 23: ...pport framing Note Ensure the inlet has at least five diameters of straight duct prior to the collector inlet including a transition to the full inlet dimensions Inlet transition should have a taper w...

Page 24: ...ded 2 Use clevis connectors not hooks on lifting slings 3 Use spreader bars to prevent damage to equipment 4 Check the Specification Control drawing for weight and dimensions of the collector and comp...

Page 25: ...ure remove the braces from the high inlet opening on the collector 2 Place 1 4 in diameter rope type sealant toward the inside and outside edge of the bolt pattern in a figure 8 pattern on the inlet s...

Page 26: ...ladder and platform components from top to bottom paying close attention to the assembly drawings 5 Make sure that all platform and ladder support brackets are installed and the bottom ladder is secur...

Page 27: ...o a customer supplied motor starter with overload and short circuit protection 4 Remove all shipping restraints from manifold arms and shipping braces from the cleaning system and cleaning system supp...

Page 28: ...ry diaphragm cap secondary diaphragm spring primary diaphragm spring secondary diaphragm metal washer facing up primary diaphragm solenoid valve air tank manifold arm see diaphragm valve assembly deta...

Page 29: ...nts The PD blower should be installed on a level surface Follow the installation instructions provided with the positive displacement blower Gauge Detail intake filter silencer positive displacement b...

Page 30: ...the preset OFF time is initiated At the end of the OFF time the timer energizes the solenoid valve to provide the ON time cleaning pulse for the diaphragm valve and repeats this cycle until the syste...

Page 31: ...2RP 88RPH 90RP 24 Spokes 132RPH 136RP 150RPH 156RP 188RPH 200RP 48 Spokes 258RPH 272RP 96 Spokes Operating Temperature Range 20 F to 180 F Solenoid Valves 120V 60 Hz intermittent duty 20 9 watts Inter...

Page 32: ...20V H1 H2 H3 H4 X1 1 2 X2 STOP FUSE START 1CRM 1CRM 1TR 1 3P OL 3P OL 3P OL 3P OL 1CRM MS1 MS3 MS1 MS4 MS2 G G Off Delay 1TRM L1 MS1 MS1 O L O L O L O L MS4 MS4 MS3 MS3 MS2 MS2 L2 L3 1 TR 1 allows cle...

Page 33: ...jury and or property damage Turn power off and lock out all power before performing service or maintenance work Do not operate with missing or damaged filters To access filters under the cleaning mani...

Page 34: ...on Company Inc 3 Tip one side of the insert into the filter opening 4 Push down on the other side of the insert to seat it against the filter lfange 5 Once all parts are seated the filter is installed...

Page 35: ...he dislodged portion The insert may need to be taken out and put back in X X 7 If the filter is not seated completely against the tubesheet see below the insert will need to be taken out and the filte...

Page 36: ...letely outside of the filter opening adjust as follows a Turn off the arm drive motor b Disable all motors and devices per site instructions c Note the starting position of the magnet d If the solenoi...

Page 37: ...escing and particulate filters can be provided with this kit Reference the plant air manifold kit drawing shipped with the collector for installation instructions Optional Plant Air Kit compressed air...

Page 38: ...gauge and bracket assembly to the supporting structure using two self drilling screws 5 Thirty five feet of plastic tubing is supplied and must be cut in two sections Connect one section of tubing fr...

Page 39: ...o avoid injury or damage when valve is operating Optional discharge devices may require independent support Discharge devices over 800 lbs must be independently supported Hopper discharge devices must...

Page 40: ...xplosion must be safely directed outdoors away from areas occupied by personnel to reduce risk of personal injury and or property damage The risk of personal injury and or property damage can be minim...

Page 41: ...s properly sealed as needed to keep the collector under operating pressure 6 Check that fan exhaust damper if applicable is set to the fully closed position 7 Check and remove all loose items in or ne...

Page 42: ...from collector as possible 2 Lock Out all energy sources 3 Remove all filters from the collector and dispose of in a suitable fashion for the dust in the collector See Filter Replacement for removal i...

Page 43: ...______________________________________________________________________________ Dust Properties Kst________________Pmax_______________ MIE_____________ MEC___________________ Accessories_______________...

Page 44: ...44 Donaldson Company Inc Service Notes Date Service Performed Notes...

Page 45: ...RP_RPH Baghouse 45 Date Service Performed Notes...

Page 46: ...46 Donaldson Company Inc Service Notes Date Service Performed Notes...

Page 47: ...oing warranty on services Products manufactured by a third party Third Party Product may constitute contain be contained in incorporated into attached to or packaged together with the goods Buyer agre...

Page 48: ...d control it is essential the user evaluate the products to determine whether the product is fit for the particular purpose and suitable for the user s application All products product specifications...