MEDIUM DUST AIR CLEANERS
www.buydonaldson.com
Engine Air Filtration
•
93
XRB Air Cleaners
Service Instructions
Check the Restriction
Replace the filter only when the
restriction level has reached the
maximum recommended by the
engine or equipment manufacturer
or on a regular service schedule.
Clean out the Vacuator
™
Valve
Remove the Vacuator Valve and
clean out any dust found in the drop
tube. Reinstall Vacuator Valve or
replace if it is worn or damaged.
Remove Service Cover
Unlatch and remove the service
cover on the air cleaner to access
the filters.
Remove the Primary
Filter
The primary filter makes such a
tight seal, that you will encounter
some initial resistance, similar to
breaking the seal on a jar. To break
the seal, grab the end of the filter
and gently move the filter from
side-to-side and pull it out of the
housing.
Application Note: Avoid dislodging
contaminant from the filter when
it is removed from the air cleaner
housing.
This servicing information is provided as a best practices guide. It is not intended to replace or supersede the service
instructions supplied by your engine or vehicle manufacturer.