FTG Air Cleaners
MEDIUM DUST AIR CLEANERS
Engine Air Filtration
•
121
www.buydonaldson.com
Tangential
Inlet
Outlet on
this end
Vacuator
™
Valve
Service
Access
Cover
The FTG Cycloflow
™
Air Cleaner
is another two-stage air cleaner
with a built-in pre-cleaner. This air
cleaner has axial seal style filters.
The FTG is typically mounted
under hood with the service cover
on the outside for access.
Applications
• Allows 32-59 m³/min. airflow
throughput per air cleaner
• Horizontal installation
• Sustained temperature tolerance:
to 82 °C
Ideal for
• Large industrial and construction
equipment: crawler tractors,
crane loaders, excavators and
air compressors with large
engines operating in severe dust
environments
• Agricultural machinery
• Mining equipment
• Oil and gas hydraulic fracturing
(fracking) equipment
• Off-highway vehicles
Air Cleaner Features
• Unique, flared inlet allows
maximum airflow with low
restriction
• 21" body diameter
• Two-stage filter system — the
first stage removes up to 85% of
incoming dust with a tangential air
inlet
• Inlet on side, outlet on end (G flow)
• Already tapped to accept filter
service indicator (1/8"-27 NPT male)
• Safety filter protects engine inlet
during filter change out
• Vacuator
™
Valve automatically
releases the pre-cleaned dust
• Housing is metal and coated with
a black, corrosion- and chemical-
resistant polymer paint
• Mounting the unit directly to the
engine is not recommended;
excessive engine vibration can
cause premature air cleaner
structural failure
Under Hood Mount, Two-Stage Filtration
For Large Construction & Mining Equipment
Accessories
• Mounting bands (order separately).
• If the installed air cleaner will be
exposed to rain, snow or debris,
an
inlet cap
can prevent moisture
ingestion.
• A
service indicator
measures the
airflow restriction across the filter,
thereby showing how much useful
life the filter has left and when to
replace the filter (see Accessories
section of this catalog).
Note:
Outlet tapped to accept filter
service indicator (1/8"-27 NPT male).
Primary Filter
Safety Filter