A23
Donaldson Company, Inc.
4. Turn the blower motor ON then OFF to check for proper rotation by referencing the rotation arrow located on the motor’s
mounting plate.
To reverse rotation, three-phase power supply: Turn electrical power OFF at source and switch any two leads on the output-
side of the blower-motor starter.
5. Connect compressed-air supply following the instructions in Compressed Air Installation.
6. With power supply ON, check the operation of the solenoid valves by turning the switch on the front of the control panel in
the HAND position and pressing the START button. The valves should open and close sequentially at factory set 10-second
intervals.
7. Turn the switch OFF.
Sprinkler
Consult with local authorities when installing fire control systems on dust collection equipment.
Sprinkler couplings are provided for the convenience of fire control system installers. The fire control system installer shall make
their own decisions on the appropriate location of fire control system components.