background image

11

Donaldson Company, Inc.

Replacement Parts

2

Printed Circuit Board

3

Plastic Tubing

1

Keypad Label

PS1

5

4 2 1

side view

autotran

BKT1

C6

R35

U6

L3

L4

L5

C16

C17

C18

R43 R42 R41

R44 R45 R46

C3

C2

Y1

D5

5 4 3 2 1

J2

U1

R50

R51

C8

R27

T36

R37

R38

RA12

U7

U2

1

2

3

4

5

6

7

8

1

2

3

4

5

1

2

3

4

5

6

7

8

RA8

RA7

RA11

ADDRESS

SW6

1

2

3

4

5

6

7

8

C14

R33 R48 R49

low

CP1

D1

D2

CR1

CR2

TB3

Mode

slave

alarm

R47

Q7

J5

7    8    9    10    11  12

hi/lo

control

alarm or

auxiliary

J3

J4

NC

2

3

NC

2

3

prog

disable

alarm

reset

3    4     5     6

R26 R28 R31 R32

R25 R39 R29 R21
R22

R23

C11

C12

TB2

3  2  1

J1

in mm

L1

L2

1    2

TB1

115/230-V

input

W1 W2

W3

115V 230V 115V

UP

DOWN

CP4

CP5

CP2

U4

U8

C15

high

Alarm

C5

R34

R16

R15

R19

R14

Cleaning

Alarm

CP3

U3

C4

Q2

Q1

Q3

Q5

Q4

"wg

mm wg

R5

R11 R6

R8

R20

Q8 Q6

R10

R4

R9

R7

LED 1

LED 2

LED 3

LED 1-3

R1R3

Q10

R13

Q9

R12

R17

R12

R30

C13 C19 C7

VR2

U5

CONN 1

R2

R40
R24

TB4

sensor out

13

+

14

GND

C10

VR1

in

out

F1

D3 D4 C1 C9

7

9

10

12

T1

1

3

4

6

A144C

M9805-02-08 REV

.

PJ1

1

2

3

4

5

Delta P Plus Control

Item Part Number

Description

Model

1

7053601

Delta P Plus Control (includes keypad label and printed circuit board)

All

2

2334200

Plastic Tubing, Vinyl, 3/16-in ID, 5/16-in OD

All

Summary of Contents for Delta P Plus

Page 1: ...roperty of the owner Leave with the unit when set up and start up are complete Donaldson Company reserves the right to change design and specifications without prior notice Illustrations are for refer...

Page 2: ...ach of these responsibilities are met As a manufacturer and supplier of Industrial Filtration Products Donaldson can assist process owners operators in the selection of filtration technologies However...

Page 3: ..._______ Other_________________________________________________________________________________ DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNIN...

Page 4: ...taining the differential pressure drop in a specified range then initiating a down time cleaning cycle when the differential pressure drop approaches zero The downtime cleaning function can be toggled...

Page 5: ...al and local codes Turn power off and lock out electrical power sources before performing service or maintenance work Do not install in classified hazardous atmospheres without an enclosure rated for...

Page 6: ...e differential pressure drop value used to start the pulse cleaning cycle 4 0 w g is a typical initial value 3 Press the MENU key three times AL appears Press the set key and the current value appears...

Page 7: ...e set as the High Set Point Hi before the downtime feature is enabled P 10 Downtime Cleaning Time 1 999 10 Minutes The amount of time the downtime cleaning will continue once the time set in P 9 expir...

Page 8: ...th a short length of tubing 3 Use the Menu key to select PAS 4 Press SET then use the arrow keys to display 4 press SET again 5 Press the MENU key repeatedly until you reach P 14 6 Press SET then use...

Page 9: ...Delta P Plus Control 6 high pressure port low pressure port clean air plenum dirty air plenum Delta P Plus Control Installation...

Page 10: ...switch Closing the switch turns the alarm OFF Internal Alarm Disable J5 To disable the alarm internally remove the jumper on MODE Jumper Block J5 located on the lower right quadrant of the circuit boa...

Page 11: ...R31 R32 R25 R39 R29 R21 R22 R23 C11 C12 TB2 3 2 1 J1 in mm L1 L2 1 2 TB1 115 230 V input W1 W2 W3 115V 230V 115V UP DOWN CP4 CP5 CP2 U4 U8 C15 high Alarm C5 R34 R16 R15 R19 R14 Cleaning Alarm CP3 U3 C...

Page 12: ...the pressure switch on the timer board to Terminals 7 and 8 on TB3 Faulty relay Using a multimeter test relay for proper closure Replace if necessary Pressure tubing disconnected ruptured or plugged...

Page 13: ...mer board s LED display If not illuminated check the supply voltage to the timer board Check the fuse on the timer board Replace if necessary Timer board defective If LEd is iluminated observe the out...

Page 14: ...reset 3 4 5 6 R26 R28 R31 R32 R25 R39 R29 R21 R22 R23 C11 C12 TB2 3 2 1 J1 in mm L1 L2 1 2 TB1 115 230 V input W1 W2 W3 115V 230V 115V UP DOWN CP4 CP5 CP2 U4 U8 C15 high Alarm C5 R34 R16 R15 R19 R14...

Page 15: ......

Page 16: ...to corrosion abrasion normal wear and tear product modification or product misapplication Donaldson also makes no warranty whatsoever as to any goods manufactured or supplied by others including elec...

Reviews: