29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia

Phone: 02 9554 9600     |     Fax: 02 9554 9433

[email protected]     |     www.domuslighting.com

Installation Manual

Note: 

 -The lamp must be installed by professional electrician

 

-Ensure the power supply is switched off before fitting this product

-Do not touch the lamp when in use

-Keep away from hot steam and corrosive gas

Specifications

Voltage: 240V AC, 50Hz

Lumen (±10%): Warm White 3000K - 1900lm

Neutral White 4000K - 2100lm

White 5000K - 2000lm

Dimmable:

No

Power:

30W

Beam Angle:

120°

IP Rating:

44

CCT: 

3000K - 4000K - 5000K (Switchable)

CRI:

≥80

Lifespan:

30,000hrs

Detection Range:

Max.12 metres at 180ᵒ scan

Duration Time adjustment:

(10±5) seconds to (4±1) minutes

Detection circuitry:

Passive Infra-Red (PIR)

MURO-PRO-30S

Order Code Product Code

Description

25062

MURO-PRO-30S-BLK-TRIO

30W Spotlight, with sensor, black finish (TRIO)

25063

MURO-PRO-30S-DGR-TRIO

30W Spotlight, with sensor, dark grey finish (TRIO)

25064

MURO-PRO-30S-WHT-TRIO

30W Spotlight, with sensor, white finish (TRIO)

Thank you for purchasing your new LED MURO-PRO-30S, Please take the time to read and understand the 

instruction sheet below. Failure to do so may void warranty.

The  Security  Light  incorporates  a  PIR  (Passive  Infra  Red)  sensing  device  which  continuously  scans  a  preset 

operating zone and immediately switches the light on when it detects movement in that area. This means that 

whenever movement is detected within the range of the sensor the light will switch on automatically to illuminate 

pathways, steps, patios, porches, or whatever area you have selected to light for reasons of safety, convenience 

or security. While there is movement within range of the unit the light will remain on.

This light is for outdoor use and only intended for normal use, must not be used for rough service (for example, 

on construction sites).

The light source of this luminaires is not replaceable; when the light source reaches its end of life the whole 

luminaire must be replaced 

To achieve best results, we suggest you take into account the following points:

•  Ideally the security lamp should be mounted 1.8 to 2.5 metres (6 to 8ft) above the ground to be scanned 

•  To avoid damage to unit - do not aim the sensor towards the sun.

•  To avoid nuisance triggering, the sensor should be directed away from heat sources such as barbecues, Air- 

  conditioners, other outside lighting, moving cars and flue vents.

•  To avoid nuisance triggering, keeping away from the area of strong electromagnetic disturbance.

•  Do not aim towards reflective surfaces such as smooth white walls, swimming pools, etc. The security lamp  

  scanning specifications (approximately 12 meters at 180°) may vary slightly depending on the mounting height  

  and location. The detection range of the unit may also alter with temperature change. Before selecting a    

  place to install your security lamp you should note that movement across the scan area is more effective than  

  movement directly toward or away from the sensor. If movement is made walking directly towards  

 

  or away from the sensor and not across, the apparent detection range will be substantially reduced.

Summary of Contents for MURO-PRO-30S

Page 1: ...e light will switch on automatically to illuminate pathways steps patios porches or whatever area you have selected to light for reasons of safety convenience or security While there is movement within range of the unit the light will remain on This light is for outdoor use and only intended for normal use must not be used for rough service for example on construction sites The light source of thi...

Page 2: ... 5 Use the plastic back box to mark the position of screw holes onto mounting surface Drill the wall to depth of about 4 cm and fit the wall plugs supplied Care should be taken to avoid drilling or screwing into concealed electrical wiring 6 Connecting the Power Cable to the Terminal Block see the relative symbol in Figure ensure the cable must drill through the Cable Gasket 7 Affix the back box t...

Page 3: ...nce which PIR Sensor can be triggered by movement body Turning the SENS knob to will decrease the sensitivity Setting the controls 1 Put the Lux control knob to light position turn the wall switch on and wait half a minute for the control circuit to stabilize At this stage ensure that the TIME control knob is set at minimum duration The security lamp will now switch on and remain on for about 30 s...

Page 4: ...sensor angle or control knob 5 Sensor positioned in wrong direction Redirect sensor and or adjust Lamp switches on for no apparent reason false trigger 1 Heat from bulb s activating sensor Adjust lamp holders to allow a Minimum gap of 40mm between LED bulb and sensor head 2 Heat sources such as air con Vents heater flues barbecues other outside lighting moving cars are activating sensor Adjust dir...

Reviews: