background image

29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia

Phone: 02 9554 9600     |     Fax: 02 9554 9433

[email protected]     |     www.domuslighting.com

Installation Manual

Note: 

 -The lamp must be installed by professional electrician

 

-Ensure the power supply is switched off before fitting this product

-Do not touch the lamp when in use

-Keep away from hot steam and corrosive gas

Electrician

•  The security lamp should be wired to its own light switch. 

•  Do not interconnect with other lights on the same switch.

•  Earth connection must be required.

•  Multiple (More than one) Muro fittings must not be wired to a separate sensor.

•  Multiple Muro Fittings cannot be wired to a single switching point.

Understanding the controls

Adjusting the duration time: The length of time that remains switched on after activation can be adjusted from 

(10±5) seconds to (4±1) minutes. Rotating the TIME knob + to -  will reduce the duration time.  

Note: Once the light has been triggered by the PIR sensor any subsequent detection will start the timed period 

again from the beginning.

Adjusting the LUX control level: The Lux control module has a built-in sensing device (photocell) that detects 

daylight and darkness. The ( ) position denotes that the floodlight can work at day and night, and the ( ) position 

only work at night. You can set to operate the unit at the desired level by adjusting the LUX knob.

Adjusting the sensitivity: The sensitivity means the Maximum distance which PIR Sensor can be triggered by 

movement body. Turning  the SENS knob + to - will decrease the sensitivity.

Setting the controls

1. Put the Lux control knob to light ( ) position, turn the wall switch on and wait half a minute for the control 

circuit to stabilize. At this stage ensure that the TIME control knob is set at minimum duration. The security lamp 

will now switch on and remain on for about 30 seconds (within 60 seconds).

2. Direct the sensor toward the desired area to be scanned by adjusting the elbow joint and swivel joint on the 

sensor arm. 

Important: loosen all lock nuts and screws on sensor and lamp before making any adjustments.

3. Have another person move across the center of the area to be scanned and slowly adjust the angle of the 

sensor arm until the unit sensors the presence of the moving person, causing the light to switch on.

4. Adjust time control to required setting.

5. To set the light level at which the lights will automatically switch “on” at night, turn the LUX control knob from 

daylight to night. If the lamps are required to switch on earlier, e. g. Dusk, wait for the desired light level, then slowly 

turn the LUX control knob towards daylight while someone walks across the center of the area to be detected. 

When the floodlights switch on, release the LUX control knob. You may need to make further adjustments to 

achieve your ideal light level setting.

Change the Color Temperature

1. Unscrew the 

Fixing Cover Screws

 then  

 

  remove the cover

2. Change the Color Temperature at back of    

  the light 

3. W: 5000K

4. NW: 4000K

5. WW: 3000K

6. Re-fit the cover.

7. Mount light onto the wall

1

2

3

4

5

6

NW  WW  W

Summary of Contents for MURO-PRO-30S

Page 1: ...e light will switch on automatically to illuminate pathways steps patios porches or whatever area you have selected to light for reasons of safety convenience or security While there is movement within range of the unit the light will remain on This light is for outdoor use and only intended for normal use must not be used for rough service for example on construction sites The light source of thi...

Page 2: ... 5 Use the plastic back box to mark the position of screw holes onto mounting surface Drill the wall to depth of about 4 cm and fit the wall plugs supplied Care should be taken to avoid drilling or screwing into concealed electrical wiring 6 Connecting the Power Cable to the Terminal Block see the relative symbol in Figure ensure the cable must drill through the Cable Gasket 7 Affix the back box t...

Page 3: ...nce which PIR Sensor can be triggered by movement body Turning the SENS knob to will decrease the sensitivity Setting the controls 1 Put the Lux control knob to light position turn the wall switch on and wait half a minute for the control circuit to stabilize At this stage ensure that the TIME control knob is set at minimum duration The security lamp will now switch on and remain on for about 30 s...

Page 4: ...sensor angle or control knob 5 Sensor positioned in wrong direction Redirect sensor and or adjust Lamp switches on for no apparent reason false trigger 1 Heat from bulb s activating sensor Adjust lamp holders to allow a Minimum gap of 40mm between LED bulb and sensor head 2 Heat sources such as air con Vents heater flues barbecues other outside lighting moving cars are activating sensor Adjust dir...