background image

INSTALLATION MANUAL

EN

- Connect the spotlights to the adaptor and using the extensions 
provided in the pack (D) following the wiring diagram:

- SLAVE:

 (fig.4) (without switch) 

- SDM:

 (fig.5) (TOUCH SENSOR master)

- WHC2:

 (fig.6) (TOUCH SENSOR change colour master)

- Connect the feeder plug (E) to an AC outlet 230V 50/60Hz. 
- Connect the device power cable to an appropriate (check plate data 
printed on the product label) safe power supply with stabilized 
voltage (not included) with power 10% higher than the total load.
- If more than one device must be connected to the power supply 
ensure that the total sum of the power absorbed by the devices 
(check the plate data shown on the product label) does not exceed 
the maximum power permitted by the Converter.

OPERATION POLAR SE SDM: 

Switching on and off takes place by simply approaching the sensitive 
IR switch (C), keeping a steady hand, faced with the same, you can 
adjust the intensity of light.
A short flash of the light indicates the achievement of maximum 
brightness.

WARNING:

Safety is guaranteed if these instructions are followed and therefore 
they must be kept. Installation may require the involvement of 
qualified personnel. Before proceeding with installation of the device 
ensure that the environmental conditions are in compliance with and 
suitable for the product characteristics. Before any operation on the 
device disconnect mains power.

CONFIGURATION:

Instructions for installation and use contained in this manual are valid 
for several configurations of the 

POLAR SE

 device, for which there are 

differences. 

POLAR SE SDM

 (touch sensor) model refers to the 

configuration of the device that includes a dimmable electronic 
switch. 

POLAR SE

 and 

POLAR XS SE

 model refers to the configuration of the 

device that does not incorporate any switch or sensor.

INSTALLATION:
POLAR SE

POLAR SE SDM 

and 

POLAR XS SE

  unit are recommended 

for installation under wall units or shelves.  Installation can be done 
with the power cable to the light positioned axially or radially with 
regard to the fitting plan.
- Fix the screws (B) supplied in the holes of the unit (A) as indicated in 
Fig. 1,2,3.

Summary of Contents for POLAR SE

Page 1: ...Via Maestri del Lavoro 1 33080 PORCIA _ PN _ Italy phone fax e mail website 0039 0434 595911 0039 0434 923345 info domusline com www domusline com MANUALE DI INSTALLAZIONE E USO INSTALLATION MANUAL IN...

Page 2: ...g administrativer Strafen mit sich die in den geltenden Richtlinien vorgesehen sind Le produit doit tre collect s par ment et non jet avec les d chets m nagers en le portant dans les d chetteries pr v...

Page 3: ...POLAR SE A B A B POLAR XS SE Fig 1 Fig 2...

Page 4: ...POLAR SE SDM A C B Fig 3 Fig 4 Converter Switch E D POLAR SE POLAR SE POLAR SE...

Page 5: ...Fig 5 Fig 6 Converter E D POLAR SE SDM C POLAR SE POLAR SE POLAR SE WHC2 SDM POLAR SE WHC2 POLAR SE WHC2 Converter E D C...

Page 6: ...the achievement of maximum brightness WARNING Safety is guaranteed if these instructions are followed and therefore they must be kept Installation may require the involvement of qualified personnel B...

Page 7: ...ee spotlight then it must be turned on via a remote switch that can be placed on the POLAR SE SDM wired in the MASTER version as shown in figure 4 or it can be assigned to a separate switch connected...

Page 8: ...and vor dem Sensor kann die Intensit t des Lichts ver ndert werden Ein kurzes Blinken der Leuchte zeigt die Erreichung der maximalen Helligkeit an WARNHINWEISE Die Sicherheit ist garantiert wenn diese...

Page 9: ...ur Verf gung Das erreichte Helligkeitsniveau wird bis zur n chsten Einstellung gespeichert Der Ausgang output cable des POLAR SE SDM kann eine maximale Last von 72W 24Vdc einschlie lich der Stromaufna...

Page 10: ...es sur la plaque du produit ne d passe pas la puissance maximale admise par le convertisseur AVERTISSEMENT La s curit est garantie condition de suivre les pr sentes instructions c est pourquoi il est...

Page 11: ...chant simplement le commutateur IR sensible garder une main ferme face la m me vous pouvez r gler l intensit de la lumi re Un bref flash de la lumi re indique la r alisation d une luminosit maximale L...

Page 12: ...icas que aparecen en la etiqueta del producto no supere la m xima admitida por el convertidor ADVERTENCIA La seguridad est garantizada si se siguen estas instrucciones por lo tanto es necesario conser...

Page 13: ...nsibles manteniendo una mano firme al frente de la misma se puede ajustar la intensidad de la luz Un breve destello de la luz p blica indica la consecuci n de la m xima luminosidad El nivel de luminos...

Page 14: ...apparecchi controllare i dati targa riportati sull etichetta del prodotto non superi quella massima ammessa dal Converter AVVERTENZA La sicurezza garantita se si seguono queste istruzioni e pertanto...

Page 15: ...o la mano all interruttore sensibile IR C mantenendo la mano ferma di fronte allo stesso si pu regolare l intensit della luce Un breve lampeggio del faretto indica il raggiungimento della massima lumi...

Page 16: ...DOMUS Line Srl Via Maestri del Lavoro 1 33080 PORCIA _ PN _ Italy phone fax e mail website 0039 0434 595911 0039 0434 923345 info domusline com www domusline com...

Reviews: