background image

INSTALLATION MANUAL

EN

- Insert the power supply cable (A) into the hole and then install 
the light (B), applying light pressure until it is completely fitted 
as illustrated in figure 2.

FLUSH INSTALLATION ON METAL SURFACES 
ATOM

 devices can be flush mounted on 0.7 mm thick (min.) 

metal surfaces and on a ø 57 mm hole as illustrated in figure 3.
- The light must be anchored to the metallic bracket by inserting 
first one spring and then the other, applying slight pressure until 
completely fitted as illustrated in figure 4.

SURFACE INSTALLATION 
ATOM

 can be surface mounted with the aid of specific supports. 

The installation can be carried out with the light power supply 
cable in both an axial or radial position with respect to the 
installation surface. In the event of a specific requirement a 
power wire exit hole can nevertheless be drilled in other 
positions as long as it does not compromise the integrity of the 
wire and/or the connector installed on it.
- Secure the plastic bracket (C) to the installation surface with 
the included screws (D); insert the light (B) into the plastic 

WARNING

Safety is guaranteed if these instructions are followed and 
therefore they must be kept. Installation may require the 
involvement of qualified personnel. Before proceeding with 
installation of the device, ensure that the environmental 
conditions are in conformity with and suitable for the 
characteristics of the product. Before any operation on the 
device disconnect mains power.

FLUSH INSTALLATION ON WOOD PANELS
ATOM

 devices can be flush mounted either on a pass-through 

hole or on a closed-end hole in wood panels. 
The installation can be carried out with the light power supply 
cable in both an axial or radial position with respect to the 
installation surface. In the event of a specific requirement a 
power wire exit hole can nevertheless be drilled in other 
positions as long as it does not compromise the integrity of the 
wire and/or the connector installed on it.
- To flush mount the device, bore a ø 57mm hole ≥ 8mm deep on 
the installation surface and then, if necessary, bore a ø ≥ 8mm 
exit hole for the power supply cable as illustrated in figure 1.

Summary of Contents for ATOM OB

Page 1: ...1 33080 PORCIA _ PN _ Italy phone fax e mail website 0039 0434 595911 0039 0434 923345 info domusline com www domusline com MANUALE DI INSTALLAZIONE E USO INSTALLATION MANUAL INSTALLATIONSHANDBUCH MA...

Page 2: ...en an den vorgesehenen Sammelstellen abgegeben werden Die angemessene getrennte Sammlung tr gt dazu bei eventuelle negative Auswirkungen auf die Umwelt und die Gesundheit zu vermeiden und die Wiederve...

Page 3: ...Fig 1 min 8mm 57mm min 8mm Fig 2 Fig 3 57mm min 0 7mm Fig 4 A B...

Page 4: ...C D ATOM OB Min 8 mm ATOM SP Fig 5 Fig 6 Min 8 mm B...

Page 5: ...astic bracket C to the installation surface with the included screws D insert the light B into the plastic WARNING Safety is guaranteed if these instructions are followed and therefore they must be ke...

Page 6: ...e device power cable to an appropriate check plate data printed on the product label safe power supply with stabilised voltage not included with power 10 higher than the total load If more than one de...

Page 7: ...en D an der Montagefl che fixieren Den Strahler B in die Kunststoffhalterung einsetzen bis dieser HINWEIS Die Sicherheit wird nur gew hrleistet wenn diese Anweisungen befolgt werden Sie sind daher auf...

Page 8: ...Bohrung mit 8 mm ausf hren siehe Abb 6 STROMANSCHLUSS DER LEUCHTE Das Netzkabel des Ger ts an ein Sicherheitsnetzteil nicht inbegriffen mit angemessener konstanter Spannung die am Etikett des Produkt...

Page 9: ...ns d autres positions condition qu elles ne compromettent MISE EN GARDE Il est important pour la s curit des personnes de suivre ces instructions et de les conserver L installation peut exiger la part...

Page 10: ...g re pression jusqu l encastrement complet comme indiqu sur la figure 5 Si besoin pratiquer pour la sortie du c ble d alimentation un trou de 8mm comme indiqu sur la figure 6 BRANCHEMENT DE L APPAREIL...

Page 11: ...as todav a es posible realizar el agujero de salida del cable de alimentaci n en ADVERTENCIA Se garantiza la seguridad si se siguen estas instrucciones y por lo tanto se las debe conservar Su instalac...

Page 12: ...ndo una ligera presi n hasta que se encaje por completo como se indica en la figura 5 En caso de ser necesario hacer un agujero de 8mm de di metro para que el cable pueda salir como se indica en la fi...

Page 13: ...altre posizioni purch non pregiudichino AVVERTENZA La sicurezza garantita se si seguono queste istruzioni e pertanto necessario conservarle L installazione pu richiedere il coinvolgimento di personale...

Page 14: ...inserire il faretto B nel supporto plastico effettuando una leggera pressione fino al completo incastro come indicato in figura 5 Se necessario praticare per l uscita del cavo di alimentazione un for...

Reviews: