Domnick Hunter CRD0245 User Manual Download Page 24

93

CRD0245---0570

,

Dimensional drawing CRD0455---0570 (Ac)

[ inches ]

mm

Summary of Contents for CRD0245

Page 1: ...anuel d utilisation NL Gebruikershandleiding SV Bruksanvisning SU K sikirja NO Brukermanual DA Brugermanual PL Instrukcja obs ugi CS N vod na obsluhu HU Haszn lati utas t s RU DATE 22 04 2008 Rev 6 CO...

Page 2: ...f seismic phenomena exist Thesafetydevicesonthe compressedair circuitmust bepro vided for by the user Only use the machine for professional work and for its intended purpose Tampering or replacement o...

Page 3: ...t local regulations 3 6 Condensate drain connection YMake the connection to the draining system avoiding con nection in a closed circuit shared by other pressurized discharge lines Check the correct f...

Page 4: ...with draining at fixed intervals 2 minutes and settable time 1 10 seconds b EXTERNAL if there is an external drain To change operating mode switchthe unitoff keeppressed and switch the machine on at t...

Page 5: ...caused by incorrect refrigerant replace ment carried out by unauthorized personnel will not be covered by the warranty YAt normal temperatureand pressure the R407Crefrigerant is a colourless gas clas...

Page 6: ...eplace pressure switch Z yes Calibrate valve Z yes no no no yes High dew point Refrigeration compressor operating HP pressure switch tripped no Fan pressure switch PV not set Replace pressure switch Z...

Page 7: ...slaufs sind vom Benutzer zu stellen DieEinheit ausschlie lichf r professionelleAnwendungen undden bei der Projektierung vorgesehenen Zweck einsetzen Eingriffe an Komponenten bzw deren Austausch durch...

Page 8: ...en des jeweiligen Installationsorts 3 6 Anschluss des Kondensatablasses Y Den Anschluss an das Ablasssystem vornehmen jedoch ver meiden dass dieser im geschlossenen Kreis zusammen mit anderen unter Dr...

Page 9: ...Sekunden b EXTERN bei Installation einer externen Ablassvorrichtung Zur nderung des Betriebsmodus die Einheit ausschalten die Taste gedr ckt halten und gleichzeitig die Einheit einschalten Im EXTERNE...

Page 10: ...ntie abgedeckt 6 2 K ltemittel Z Auff llen von K ltemittel f r eventuelleSch den durchfehlerhafte Bef llung mit K ltemittel durch unbefugtes Personal werden keine Garantieanspr che anerkannt Y Das K l...

Page 11: ...il einstellen Z ja nein nein nein ja Hoher Taupunkt K lteverdichter in Betrieb Hochdruck w chter HP ausgel st nein Druckw chter Ventilator PV unkorrekt eingestellt Druckw chter ersetzen Z ja nein Nied...

Page 12: ...Massima pressione di esercizio lato aria Presi n m xima de trabajo lado aire Press o m xima de funcionamento do lado do ar j j Air side max working pressure Max Betriebsdruck auf Druckluftseite Pressi...

Page 13: ...r de iflg normen ISO 3746 Poziom ci nienia akustycznego w odleg o ci 1 metr w wolnym polu wed ug normy ISO 3746 Hladina zvukov ho tlaku ve vzd lenosti 1 m ve voln m prostoru podle normy ISO 3746 Hangn...

Page 14: ...cheider Separator Erotin Adskiller Udskiller Oddzielacz Odlu ova Szepar tor 7 Capillare espansione Capilar expansi n Tubo de expans o j j Expansion capillary Expansions Kapillare Tube de d tente Expan...

Page 15: ...pskran Hane for kondensvandsafl b Kurek spustu kondensatu Kohoutek odvodu kondenz tu Kondenzv z leereszt csap 24 Presa di pressione Toma de presi n Tomada de press o j Pressure point Druckanschluss Pr...

Page 16: ...presentes en el modelo con sistema de drenaje TEMPORIZADO Para los dispositivos de drenaje externos consulte el manual de f brica respectivo Componentes existentes nos modelos com descar regador TEMP...

Page 17: ...r Trocknereinheit Soupapes de s curit pour ne pas d passer la pression pr tablie du s cheur Veiligheidskleppen om de toegestane max druk in de droger niet te overschrijden Tubi flessibili per connessi...

Page 18: ...at rezg snek van kit ve D mpare av l mplig typ om n tet uts tts f r sv ngningar Sopivat v r htelynestolaitteet jos putkisto altistuu virtausv r htelyille Egnede dempere dersom nettet er utsatt for svi...

Page 19: ...stallation temperature pressure F L A A 230V 10 1Ph 50Hz for eletrical connection Compressed air inlet outlet Condensate drain pressure level R407C kg In Max mm2 dB A CRD0245 65 1 0 4 2 CRD0300 66 0 8...

Page 20: ...73137 c Refrigerant condenser 2 114736 114726 114727 Evaporator Separator Air air heat exchanger 4 5 10 473507 473508 473065 Refrigerant filter 8 206219 Fan pressure switch 12 354055 ts High pressure...

Page 21: ...CRD0245 0570 90 8 5 Exploded drawing CRD0245 0360 Ac...

Page 22: ...91 CRD0245 0570 Exploded drawing CRD0455 0570 Ac...

Page 23: ...CRD0245 0570 92 8 6 Dimensional drawing CRD0245 0360 Ac inches mm...

Page 24: ...93 CRD0245 0570 Dimensional drawing CRD0455 0570 Ac inches mm...

Page 25: ...CRD0245 0570 94 8 7 Refrigerant circuit CRD0245 0360 Ac A1...

Page 26: ...95 CRD0245 0570 Refrigerant circuit CRD0455 0570 Ac A1...

Page 27: ...CRD0245 0570 96 8 8 Wiring diagram CRD0245 0360 0455 0570 Ac Sheet 1 of 3...

Page 28: ...97 CRD0245 0570 Wiring diagram CRD0245 0360 0455 0570 Ac Sheet 2 of 3...

Page 29: ...CRD0245 0570 98 Wiring diagram CRD0245 0360 0455 0570 Ac Sheet 3 of 3 315mA 250V...

Page 30: ...99 CRD0245 0570 Wiring diagram CRD0300 Ac Sheet 1 of 3...

Page 31: ...CRD0245 0570 100 Wiring diagram CRD0300 Ac Sheet 2 of 3...

Page 32: ...101 CRD0245 0570 Wiring diagram CRD0300 Ac Sheet 3 of 3 315mA 250V...

Page 33: ...of Parker Hannifin ltd domnick hunter has a continuos policy of product development and although the Company reserves the righ to change specification it attempts to keep customer informed of any alt...