EN
Servicing the generator
TEC29EV
22
10
Servicing the generator
I
10.1
Maintenance table
!
I
NOTE
Find your Dometic service partner on the internet:
http://service-location.dometic.com
WARNING!
Only have maintenance work carried out by specialist personnel
who are familiar with the relevant regulations. Inadequate mainte-
nance may cause serious hazards.
NOTE
Have the following maintenance work performed at regular inter-
vals or after the specified number of operating hours, whichever
is sooner.
Interval
Inspection/maintenance
In the first
month or after
20 hours
➤
Change the oil.
➤
Check the air filter (chapter “Servicing the air filter (fig.
7
,
page 6)” on page 25).
Every 3 months
or after
50 hours
➤
Check the air filter (chapter “Servicing the air filter (fig.
7
,
page 6)” on page 25).
Every 6 months
or after
100 hours
➤
Change the oil.
➤
Check the spark plug (chapter “Servicing the spark plugs” on
page 26).
Once a year or
every 300 hours
➤
Check the valves‘ adjustment.
➤
Check the fuel tank and fuel filter.
➤
Check the vibration damper.
Every two years
➤
Check the petrol supply lines.