![Dometic TEC29EV Operating Manual Download Page 15](http://html1.mh-extra.com/html/dometic/tec29ev/tec29ev_operating-manual_2518760015.webp)
EN
TEC29EV
Operating the generator
15
Displays
8
Operating the generator
A
I
8.1
Basic notes on operation
!
Please note the following basic information:
Always check the oil level before use (chapter “Checking the oil level” on
page 19).
Even small overloads in the long-run will cause the cut-out switch to
trigger.
Leave the generator running for a few minutes after use without any
consumers before stopping it.
No. in
fig.
3
,
page 4
Description
6
AC supply
Actual voltage output
7
Constant output
Current capacity of connected consumer
8
Operating hours
Time the generator is in operation
9
DC voltage
Battery voltage
10
Messages
Status reports of the generator (see
chapter “Display messages” on page 17)
NOTICE!
Do not run the generator over 70 % of the maximum constant out-
put for the first 50 operating hours (run-in phase).
NOTE
Run the generator at a maximum of approx. 75 % of the maximum
continuous load after the run-in phase.
By doing this you can prolong the service life of the generator and
maximise its efficiency.
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the
intake grille.