EN
PerfectCharge MCP1204/1207
Troubleshooting
19
10
Troubleshooting
!
I
The red LED indicates a fault:
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
NOTE
If you have detailed questions about the
battery charger
data
, please
contact the manufacturer (addresses on the back of the instruction
manual).
LED display
Cause
Remedy
Flashing
Inverse polarity
Check the cables and connections.
Flashing
Battery voltage < 9 V
The battery cannot be charged.
Replace the battery.
Constantly lit
Battery no longer connected
The connection to the battery was
disconnected during the charging
process.
Check the cables and connections.
Fuse in the connection cable
was tripped
Replace the fuse (10 A plug-in fuse for
vehicles)
MCP1204-1207--O-16s.book Seite 19 Freitag, 10. März 2017 12:04 12
Summary of Contents for SINEPOWER MCP1204
Page 2: ......
Page 5: ...PerfectCharge MCP1204 1207 5 3 A B 2 1 3 1 2 1 3 2 5...
Page 198: ...RU PerfectCharge MCP1204 1207 198 1 D A I 2 2 1...
Page 199: ...RU PerfectCharge MCP1204 1207 199 2 2 D IP65 8...
Page 200: ...RU PerfectCharge MCP1204 1207 200 A 2 3 D...
Page 201: ...RU PerfectCharge MCP1204 1207 201 2 4 D A...
Page 202: ...RU PerfectCharge MCP1204 1207 202 2 5 A...
Page 203: ...RU PerfectCharge MCP1204 1207 203 3 4 1 3 1 2 12 3 4 9600000094 9102500079...
Page 204: ...RU PerfectCharge MCP1204 1207 204 5 12 AGM A 9102500079 NiCd NiMH...
Page 205: ...RU PerfectCharge MCP1204 1207 205 6 1 14 4 2 14 7 AGM 3 13 7...
Page 206: ...RU PerfectCharge MCP1204 1207 206 6 1 I 2 3 1 207 2 1 1 2 5 3 10 3 230 4 12 5...
Page 209: ...RU PerfectCharge MCP1204 1207 209 8 Maintenance 12 8 14 4 7 A 7 1 230 12...
Page 211: ...RU PerfectCharge MCP1204 1207 211 8 I 8 1 5 5 1 2 3 5 5 3...
Page 212: ...RU PerfectCharge MCP1204 1207 212 8 2 I 210 9 A...
Page 213: ...RU PerfectCharge MCP1204 1207 213 10 I 9 10...