EN
RM5310, RM5330, RM5380
Safety instructions
89
2.4
Operating the device safely at 230 V
w
A
NOTICE!
Only connect the unit to the AC mains with the appropriate
connection cable.
Never pull the plug out of the socket by the connection cable.
If the connection cable is damaged, it must be replaced with a
connection cable of the same type and specification by qualified
employees in order to prevent safety hazards.
Before starting the device, ensure that the power supply line
and the plug are dry.
Check that the voltage specification on the type plate is the
same as that of the power supply.
2.5
Operating the device safely with gas
A
NOTICE!
Never check the device for leaks with an open flame.
Use only propane or butane gas (
no
natural gas).
The device may
only
be operated at the pressure specified on
the type plate. Use a DIN-DVGW-approved pressure regulator
with permanent settings in line with DIN EN 12864.
Never
store liquid gas cylinders in unventilated places or below
ground level (funnel-shaped pits in the ground).
Keep liquid gas cylinders away from direct sunlight. The
temperature may not exceed 50 °C.
It is not permitted to operate the device with gas on ferries and
at petrol stations.
If you smell gas:
– Close the shut-off valve on the gas supply and the cylinder
valve.
– Open the windows and leave the room.
– Do not operate any electrical switches.
– Extinguish open flames.
– Have the gas system checked by a specialist company.