background image

6

If the refrigerator is not cooling sufficiently, the reason 

 

may be:

• 

Inadequate ventilation of the cooling unit due to the in-

take and/or exhaust air vents being partly or completely 

blocked.

• 

The evaporator is frosted up.

• 

The thermostat setting is incorrect.

• 

Gas pressure is incorrect - please check the pressure-

regulator on the gas container.

• 

The refrigerator is not level.

• 

Too much food is loaded at one time.

• 

The door is not properly closed or the magnetic sealing 

strip is defective.

If the refrigerator still does not work properly, call a service

technician. 

INSTALLATION INSTRUC-

TIONS

GENERAL INFORMATION

The refrigerator is intended for installation in a motor 

home / caravan, and the information relates to this appli-

cation. A correct installation is important for correct opera-

tion of the appliance. 

The refrigerator must be installed on a solid floor and must 

be level. With the vehicle carefully leveled, the refrigerator 

should be level both ways in the freezer compartment. 

Free air circulation over the fins of the cooling unit is es

-

sential.

VENTILATION OF THE UNIT

VENTILATION GRILLES

We  recommend  fitting  the  Dometic  ventilation  systems, 

which are specially developed by Dometic for this pur-

pose. The Dometic ventilation grilles permit inspection 

and small repairs to be carried out without the necessity 

of removing the refrigerator from the recess. 

If there is no outer grille at floor level where leaking gas 

can escape, a 40 mm hole to the outside should be made 

in the floor of the recess to drain any unburned gas to the 

outside. Fit the hole with wire mesh and an angled plate 

to protect it from stones, mud etc.

SIDE VENTILATION (OPTION ONE)

The refrigerator unit is ventilated via two openings in the 

wall of the motorhome / caravan. Fresh air enters through 

the lower opening and warm air is discharged through the 

upper one. Exhaust gases must be vented through the 

wall to the outside of the vehicle. Dometic wall venting 

systems provide provision for venting the exhaust gases. 

Consult your Dometic representative for further informa-

tion.

The lower opening should be located at floor level (to al

-

low any leaking gas to escape to the outside). The upper 

ventilation opening should be located above the conden-

ser, as high as possible, to ensure good ventilation. We 

recommend Dometic ventilation kits.

ROOF VENTILATION (OPTION TWO)

The ventilation of the cooling unit can also be done via 

one opening in the wall of the motor home and one on the 

roof for the roof vent.

Fresh air enters through the lower opening and warm air 

is discharged through the roof vent. The lower opening 

should be located at floor level (to allow any leaking gas 

to escape to the outside). We recommend the Dometic 

motor home wall and roof top ventilation system.

MAINTENANCE

• 

This appliance must be serviced by an authorized per-

son. We recommend that an authorized service techni-

cian checks the refrigerator once a year.

• 

The “Installation and operating instructions manual” 

should always be available. 

• 

Ensure that the gas safety shut-off valve is working pro-

perly.

• 

Make sure that the ventilation openings are unobstruc-

ted.

• 

See to it that the burner is clean and free from combus-

tible material.

SERVICE AND SPARE PARTS

Service and spare parts are obtainable from your dealer 

or Dometic - consult the telephone directory.

The sealed cooling system must not be opened, since 

it contains corroding chemicals under high pressure.

Summary of Contents for RM 4601

Page 1: ...gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Improper installation adjustment alteration service or maintenance can cause injury or property damage Ref...

Page 2: ...t later than seven days after the refri gerator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model and that it is suita ble for the...

Page 3: ...HE REFRIGERATOR LP GAS OPERATION After initial installation servicing or changing gas cylin ders etc the gas line is likely to be filled with air You may have to repeat the lighting procedure several...

Page 4: ...ever put hot food in the refrigerator allow it to cool first The frozen food compartment is intended for the storage of frozen food and for making ice Most kinds of frozen food can be stored in the fr...

Page 5: ...that The refrigerator is not operating on 12V when the ve hicle is parked otherwise you will drain the car battery in a short time Defrosting is carried out periodically The refrigerator is clean and...

Page 6: ...t it from stones mud etc SIDE VENTILATION OPTION ONE The refrigerator unit is ventilated via two openings in the wall of the motorhome caravan Fresh air enters through the lower opening and warm air i...

Page 7: ...n properly ventilated Fig 2 Minimum ventilation height Minimum ventilation height Option two Option one RM4601 1417 mm Warm air deflecting plate RM4601 1577 mm CLEARANCES Minimum clearances mm to comb...

Page 8: ...must be taken to insure the warm air de flecting plate can not damage wires or tubes on top of the refrigerator cabinet SECURING THE REFRIGERATOR For the best cooling performance the installer must bl...

Page 9: ...be on the outlet side of the cock and the pipework should be positioned so as not to prevent the refrigerator from being readily withdrawn All completed connections should be checked for leaks with s...

Page 10: ...must be used to reverse the doors For further information please contact your dealer MOUNTING DOOR PANEL The refrigerator is delivered with door panels Door pan els can easily be fitted or changed Th...

Page 11: ...se and then remove the shelf locks from the wire shelf 2 Tilt the shelf to one side at an angle while pul ling forward 3 Reposition the shelf in the desired location Insert the ends of the wire shelf...

Page 12: ...12 APPENDIX A WIRING DIAGRAM...