10
1
2
2
3
3
4
5
Model
Fuse size (A)
RM4601
30
Cross-section
The wires connected to this terminal must have the fol-
lowing minimum cross-section area:
Maximum length of 8 meters from the refrigerator to the
battery. 10 mm
2
cross-section low voltage multi strand ca-
ble.
Cable lengths > 8 meters will require a larger cross-sec-
tional cable.
Connect two wires at the refrigerator and route directly
to the 12 volt DC supply. To prevent the refrigerator from
draining the battery, make sure that the current supplied
to the motor home / caravan is cut off when the vehicle
engine is not running, for example by fitting an ignition
control relay.
Before leaving
Once the installation is complete, test the operation of the
refrigerator and instruct the user on its correct operation.
If the appliance fails to operate correctly, contact your lo-
cal Dometic Service provider.
MOUNTING INSTRUCTIONS
REPOSITIONING THE HINGES
The refrigerator is equipped with reversible doors. A spe-
cial door reversing kit must be used to reverse the doors.
For further information, please contact your dealer.
MOUNTING DOOR PANEL
The refrigerator is delivered with door panels. Door pan-
els can easily be fitted or changed. The dimensions of the
panels must be:
Height
upper door
402
± 1
mm
lower door
826
± 1
mm
Width
525
± 1
mm
Thickness max.
4 mm
When mounting the panel, proceed as follows:
1. Open the door 90 degrees.
2. Remove the door decoration strip (2) by gen-
tly pushing the four tabs away with a flat blade
screwdriver (1).
3. Insert the vertical edges into the grooves of
the door frame (3).
4. Push the panel downward so that the lower
horizontal edge of the panel (4) is fitted into
the bottom grove (5).
5. Snap in the decoration strip (2).
12V SUPPLIES
The 12V connection of the refrigerator is shown in fig. 12.
Connect the refrigerator to the vehicle battery or alterna-
tor by a direct cable; (check the polarity). The connection
is made to the terminal block.
The connection is made to the positive (+) and negative (-)
terminals of the terminal block. Correct polarity must be
observed when connecting to the 12 volt DC supply. Do
not use the chassis or the vehicle frame as one of the
conductors.
12 V DC
Reigniter
Lamp
Heater
FIG. 12
Summary of Contents for RM 4601
Page 12: ...12 APPENDIX A WIRING DIAGRAM...