17
15°C
27.8
Ω
20°C
27.9
Ω
- Disconnect the end of evaporator sensor cable from sensors marked X8
on Fuzzy PCB
(Figure 46)
- Turn refrigerator back on its feet, open door.
- Remove cover panel from refrigerator.
(Figure 47)
- Remove evaporator board from evaporator pipe, remove sensor tip from
sensor seating
(Figure 48, 49)
- Pull sensor from the cabinet body in the direction of the back panel.
- Thread new sensor to cabinet body, place sensor tip in evaporator board
seating, reassemble evaporator board and cover panel.
- At the back, connect evaporator plug to the Fuzzy panel, clip panel back
on.
Figure 47
Figure 48
Figure 49
Figure 46