background image

4

General

• The RCCA920 is intended to be used for transport of chilled drinks. It is equipped

with a DC-compressor powered by 2 rechargeable deep cycle batteries. 

• The refrigeration system is placed on top of the unit with the evaporator inside the

cabinet.

• Sufficient room is required around the unit to ensure adequate air circulation.

Please refer to the installation information regarding this point.

• When the door is open, hot air will flow inside the cabinet and increase the

temperature of the ambient air; however, this will hardly affect the core

temperature of the goods inside if the door is closed rapidly. To minimise this

exchange with outside ambient air, the evaporator fans are designed to stop

running, when the door is open.

• It is recommended to place the drinks in original packaging.

• Store the items within the appliance so that the air can circulate around.

• During normal operation, small quantities of condensation water may flow out of

the drainage hose at the back of the unit.

• The RCCA-920 complies with climate class 5 according to ISO23953-2 which means

that it can be operated in an ambient temperature up to 40°C  with a relative

humidity of  40%. Fully functional performance however is maintained up to 45°C

ambient.

Safety

• Before using the unit, read these operating instructions carefully, including all the

information on safety, operation and maintenance.

• Keep these operating instructions ready readily accessible and with the appliance,

so that all users understand the functions and safety regulations.

• To prevent the unit from tilting, it must never be moved on a diagonal level of more

than 20°.   

• Before connecting, opening and using the unit, it must be standing on a horizontal

surface.

• Never lock anybody inside. Danger of suffocation!

• Pay attention to all moving parts when closing the door. Keep hands and fingers

clear when operating the closing mechanism. 

• Do not lift the unit manually. Use a fork lift to lift and move equipment. A fork lift

can be used on all four sides of the unit.   

• The unit must only be used in an upright position. It must not be used as a chest.

• All installation work and adjustments to the unit must only be carried out by

qualified personnel. Work performed by persons with insufficient technical

knowledge may adversely affect the performance of the unit or cause physical

injury or damage to the equipment.

• The units must only be used by adults. Do not allow children to play with the units

or touch the controls.

• Any maintenance as well as any repair operation are only permitted by Dometic

personnel, by Dometic authorised subcontractors or if the user has been properly

trained. Only genuine spare parts must be used.

Summary of Contents for RCCA 920

Page 1: ...820 9506 00 ed0513 RCCA 920 Operating instructions ...

Page 2: ...2 ...

Page 3: ...g the batteries 6 Battery Guard 7 Operation 7 Control Panel 7 Charging LED 7 Electronic Control Unit 7 Switching on 8 Temperature Setpoint 8 Door Switch 8 Alarms 8 Temperature Alarm 8 Door Alarm 9 Alarm in the Event of Sensor Failure 9 Temperature history 9 Fan 10 Door lock 10 Automatic Defrosting 10 Cleaning 10 Maintenance 11 Address for service 11 Technical Data 11 ...

Page 4: ...ient Safety Before using the unit read these operating instructions carefully including all the information on safety operation and maintenance Keep these operating instructions ready readily accessible and with the appliance so that all users understand the functions and safety regulations To prevent the unit from tilting it must never be moved on a diagonal level of more than 20 Before connectin...

Page 5: ...ransit If you are unsure contact your sales outlet and ask them The unit must only be transported in an upright position and with closed door Environmental Protection Make your contribution to saving the environment Bear in mind that orderly and proper disposal is required Packaging materials and devices are always recyclable and should be taken for recycling Before scrapping an old unit remove th...

Page 6: ...rcuit The circuit breaker is located on the backside of the refrigerator IMPORTANT On delivery the circuit breaker is in OFF position Before connection to AC make sure that the circuit breaker is switched to ON position If the circuit breaker is switched on afterwards the batteries will not charge There is no need to switch the circuit breaker off at any time Leave it in ON position during normal ...

Page 7: ...harging LED The LED indicates the status of the battery charging process Yellow LED charging in process Green LED charging completed The LED only lights up if AC is connected The LED is off during normal operation of the unit using battery power For optimal battery performance the unit should only be disconnected from AC and put into operation when the LED has changed to green Electronic Control U...

Page 8: ...r being sucked into the refrigerator An excessive door opening time will trigger a door alarm Alarms When an alarm situation occurs attempts must be made to find the cause of the alarm and rectify it as soon as possible If unable to do so the necessary measures must be taken immediately so that the goods stored are not damaged Temperature Alarm If the inside temperature of the appliance goes above...

Page 9: ...lure If the temperature sensor fails or is defective a sensor alarm is generated by the electronics The display shows the error message P1 As the control sensor is no longer working the appliance is regulated by a preprogrammed ON OFF mode Together with the error message on the display an acoustic alarm sounds This acoustic alarm can be muted by pressing any button on the electronics for 30 minute...

Page 10: ...e the compressor is switched off until the temperature reaches a predefined value If this temperature is not achieved after a certain timeout the appliance is switched on again During a defrosting process the defrosting symbol is shown in the display The defrost water is evacuated through the drainage tube at the rear of the appliance Cleaning The equipment should be cleaned inside and outside bef...

Page 11: ...tre with exclusive use of original spare parts When replacing the batteries it must be ensured that they are replaced by batteries of the same type AGM type deep cycle min 100 Ah Address for service Regular Service Coca Cola Amatil 40 Mount Street North Sydney NSW 2060 Phone 132653 Further Assistance Dometic Australia Phone 1800 21 21 21 Technical Data Designation RCCA 920 External Dimensions WxDx...