background image

10

Fan

• The  RCCA-920  is equipped with internal ventilation. For optimal air circulation

inside, it is important that the interior fan is always functional.

• To prevent warm outside air being sucked in unnecessarily when the door is open,

the fan switches off when the door is opened.

• The airflow to the fan must never be impeded. The ventilation slots must therefore

never be blocked or covered.

• The fan symbol  

is displayed as soon as the fan is running.

Door lock

•  The door of the appliance is equipped with a magnetic door gasket. For transport

purposes, the door must be firmly locked with the locking lever.

•  The door locking system is designed in such a way, that no person can accidently

be locked inside. The door can be opened from inside by means of the inside lever. 

Automatic Defrosting

• The unit is equipped with automatic defrosting. After specified run time, the

compressor is switched off until the temperature reaches a predefined value. If

this temperature is not achieved after a certain timeout, the appliance is switched

on again. 

• During a defrosting process the defrosting symbol  

is shown in the display.

• The defrost water is evacuated through the drainage tube at the rear of the

appliance. 

Cleaning

• The equipment should be cleaned inside and outside before first time use and at

regular intervals thereafter.

• Only use neutral (food-safe) cleaning agents. Never use aggressive or caustic

cleaning agents, scouring powder, steel wool, abrasive sponges or chemical

solvents. When cleaning, make sure that no fluids of any kind run into the

ventilation housing. After cleaning the unit must be completely dried.

• Remove any food leakage immediately.

• The use of a high pressure cleaner and/or a steam jet is strictly forbidden. 

•  Clean the unit and leave the door slightly opened before any long term storage

unplugged. 

• If the appliance needs to be disinfected, we recommend to use any commonly used

disinfecting agents.  

AUX

AUX

Summary of Contents for RCCA 920

Page 1: ...820 9506 00 ed0513 RCCA 920 Operating instructions ...

Page 2: ...2 ...

Page 3: ...g the batteries 6 Battery Guard 7 Operation 7 Control Panel 7 Charging LED 7 Electronic Control Unit 7 Switching on 8 Temperature Setpoint 8 Door Switch 8 Alarms 8 Temperature Alarm 8 Door Alarm 9 Alarm in the Event of Sensor Failure 9 Temperature history 9 Fan 10 Door lock 10 Automatic Defrosting 10 Cleaning 10 Maintenance 11 Address for service 11 Technical Data 11 ...

Page 4: ...ient Safety Before using the unit read these operating instructions carefully including all the information on safety operation and maintenance Keep these operating instructions ready readily accessible and with the appliance so that all users understand the functions and safety regulations To prevent the unit from tilting it must never be moved on a diagonal level of more than 20 Before connectin...

Page 5: ...ransit If you are unsure contact your sales outlet and ask them The unit must only be transported in an upright position and with closed door Environmental Protection Make your contribution to saving the environment Bear in mind that orderly and proper disposal is required Packaging materials and devices are always recyclable and should be taken for recycling Before scrapping an old unit remove th...

Page 6: ...rcuit The circuit breaker is located on the backside of the refrigerator IMPORTANT On delivery the circuit breaker is in OFF position Before connection to AC make sure that the circuit breaker is switched to ON position If the circuit breaker is switched on afterwards the batteries will not charge There is no need to switch the circuit breaker off at any time Leave it in ON position during normal ...

Page 7: ...harging LED The LED indicates the status of the battery charging process Yellow LED charging in process Green LED charging completed The LED only lights up if AC is connected The LED is off during normal operation of the unit using battery power For optimal battery performance the unit should only be disconnected from AC and put into operation when the LED has changed to green Electronic Control U...

Page 8: ...r being sucked into the refrigerator An excessive door opening time will trigger a door alarm Alarms When an alarm situation occurs attempts must be made to find the cause of the alarm and rectify it as soon as possible If unable to do so the necessary measures must be taken immediately so that the goods stored are not damaged Temperature Alarm If the inside temperature of the appliance goes above...

Page 9: ...lure If the temperature sensor fails or is defective a sensor alarm is generated by the electronics The display shows the error message P1 As the control sensor is no longer working the appliance is regulated by a preprogrammed ON OFF mode Together with the error message on the display an acoustic alarm sounds This acoustic alarm can be muted by pressing any button on the electronics for 30 minute...

Page 10: ...e the compressor is switched off until the temperature reaches a predefined value If this temperature is not achieved after a certain timeout the appliance is switched on again During a defrosting process the defrosting symbol is shown in the display The defrost water is evacuated through the drainage tube at the rear of the appliance Cleaning The equipment should be cleaned inside and outside bef...

Page 11: ...tre with exclusive use of original spare parts When replacing the batteries it must be ensured that they are replaced by batteries of the same type AGM type deep cycle min 100 Ah Address for service Regular Service Coca Cola Amatil 40 Mount Street North Sydney NSW 2060 Phone 132653 Further Assistance Dometic Australia Phone 1800 21 21 21 Technical Data Designation RCCA 920 External Dimensions WxDx...