EN
PerfectCharge
Connect charging converter
19
Determine cable cross-section
I
The minimum cable cross-section depends on the maximum cable length:
9.1
Connect charging converter
A
➤
Connect the charging converter as shown:
–
Correct connection diagram: fig.
4
, page 5
–
Connecting the batteries: fig.
5
, page 6
–
Connect control line (I1): fig.
6
, page 6
9.2
Connect accessories
I
➤
Connect the accessory to the following contacts:
–
Performance regulation (I2): fig.
1
5, page 3
–
Temperature sensor: fig.
1
6, page 3
NOTE
Keep the distance to the body battery as short as possible.
Cable length
Minimum cable cross-section/Fuse
2.5 mm² /
30 A
4 mm² /
40 A
6 mm² /
60 A
10 mm² /
80 A
DCCxxxx-10
to the starter battery
7 m
11 m
16 m
–
to battery structure
2 m
3.5 m
5 m
–
DCC xxxx–20
to the starter battery
–
5.5 m
8 m
14 m
to battery structure
–
1.5 m
2.5 m
4 m
DCCxxxx-40
to the starter battery
–
–
–
7 m
to battery structure
–
–
–
2 m
NOTICE!
The charging converter must not be connected directly to the alternator.
NOTE - Performance regulation
To limit the output current of the charging converter to 5 A, a positive
control signal must be present at contact “I2” (fig.
1
5, page 3).
DCC1224-2424--IO-16s.book Seite 19 Donnerstag, 8. März 2018 3:06 15