EN
Charging
PBC110
12
6.2
Charge rate
The following maximum capacities are to be used as a general guide:
6.3
Settings
➤
Using the battery type selector (4) choose the battery type to be used, see
fig.
➤
Using the charge rate selector (5) choose the charge rate to be used, see fig.
7
Charging
7.1
Electrolyte level check and precharge check
➤
Only for Flooded or WET battery: Check the battery electrolyte level.
If necessary, remove the vent caps and add distilled water so the levels are half-
way between the upper and lower fill lines.
➤
Check the battery label for battery type and capacity. Only charge 12 V lead acid
(GEL, WET, AGM) or LiFePO4 batteries.
➤
Ensure that the battery charger is not connected to mains power.
7.2
Connect the battery charger to the battery
!
WARNING!
• Only use the device indoor. Do not expose the battery charger to rain,
snow and liquids.
• Explosive gases may escape from the battery during charging. Pro-
vide good ventilation to prevent flames and sparks.
• When connecting to the battery, the battery charger must not be con-
nected to mains power.
Setting
Battery capacity/Charging
Battery capacity/Maintaining
2 A
6 – 20 Ah
6 – 20 Ah
5 A
21 – 50 Ah
21 – 60 Ah
10 A
51 – 200 Ah
61 – 240 Ah