EN
Micro Heki
Mounting the Micro Heki
7
7
Mounting the Micro Heki
Supplementary to fig.
3
➤
Measure your roof thickness W.
➤
Use the appropriate installation kit.
See fig.
4
➤
Check that the roof light has sufficient space around it (approx.1 to 2 mm) in the
wall section.
See fig.
5
➤
Clean the roof opening in the mounting area.
See fig.
6
A
➤
Seal the mounting frame with a flexible non-hardening sealing compound (e.g.
SikaLastomer-710).
W
W
23 – 25 mm
9104118048
43 mm
9104 9104118059
26 – 27 mm
9104118049
44 – 45 mm
9104 9104118059
28 – 29 mm
9104118050
46 – 47 mm
9104 9104118059
30 – 31 mm
9104118051
48 – 49 mm
9104 9104118059
32 – 33 mm
9104118052
50 – 51 mm
9104 9104118059
34 – 35 mm
9104118053
52 – 53 mm
9104 9104118059
36 – 37 mm
9104118054
54 – 55 mm
9104 9104118059
38 – 39 mm
9104118055
56 – 57 mm
9104 9104118059
40 – 41 mm
9104118056
58 – 59 mm
9104 9104118059
42 mm
9104118057
60 mm
9104 9104118059
NOTICE!
Observe the sealant manufacturer's instructions.
Micro-Heki--IO-16s.book Seite 7 Dienstag, 13. Februar 2018 5:56 17