EN
MD 310, MD390, MD450
Installing safe
9
•
Avoid damp ambient conditions (e.g in the bathroom and swimming pool) in
order to avoid condensation forming in the device.
•
Select a fastening material (screws with plugs, if necessary) which is appropriate
for the base.
7.2
Attaching the safe
➤
Select a suitable installation location.
➤
Select an appropriate method for installation (attachment on the rear or on the
underside).
➤
Mark the drill holes according to the table below
Drilling on the rear (fig.
2
, page 3)
Drilling on the underside (fig.
3
, page 3)
➤
Pre-drill the hole in the mounting location (e.g. in the wall or cupboard).
➤
Attach the safe with a suitable fastening material.
Model
MD450
MD390
MD310
H
100 mm
100 mm
82.5 mm
L1
120 mm
90 mm
50 mm
L2
210 mm
210 mm
210 mm
Model
MD450
MD390
MD310
L1
120 mm
90 mm
50 mm
L2
210 mm
210 mm
210 mm
P
200 mm
235 mm
117.5 mm
XSafe-MB.book Seite 9 Freitag, 16. September 2016 1:53 13