![Dometic MD310 Installation And Operating Manual Download Page 13](http://html.mh-extra.com/html/dometic/md310/md310_installation-and-operating-manual_2519518013.webp)
EN
MD 310, MD390, MD450
Using the safe
13
8.3
Emergency opening with the master key
A
The safe lock can be opened in all eventualities with the master key, even in the event
of an electronic fault.
Opening the safe with the master key
➤
Slide the plastic cover which covers the key hole (fig.
1
5, page 3).
➤
Put the master key into the key hole.
➤
Open the safe lock by turning the master key 90° to the left (fig.
4
, page 4) until
the bolts slide completely home.
✓
The bolts extend mechanically.
Emergency opening with the master key giving a new user code
➤
Slide the plastic cover which covers the key hole (fig.
1
5, page 3).
➤
Put the master key into the key hole.
➤
Open the safe lock by turning the master key 90° to the left (fig.
4
, page 4) until
the bolts slide completely home.
➤
Keep the master key in this position and open the door.
➤
Enter a new four digit code.
➤
Press the
CLOSE
button.
✓
The display shows the message
CLOSED
.
✓
The display shows the message
E-RUN
.
➤
Close the safe door.
➤
Remove the master key.
NOTICE!
No unauthorised persons should have access to the master key.
Store the master key very carefully in a safe location.
XSafe-MB.book Seite 13 Freitag, 16. September 2016 1:53 13